Operation
The remote rmware update is loaded to the Data
platform.
In the F
D
IRMWARE
OWNLOA D
F
D
S
IRMWARE
OWNLOA DED
update le has been sent to the
The download of the rmware update to the device
memory starts automatically as soon as the device
is online.
During the rmware update, the LEDs light up in a
certain sequence.
INFORMATION
For more information on the LED status indications, see
chapter Indicator elements (LED).
The device is restarted.
After the restart, the device uses the updated
rmware version.
14. In the S
> D
ERVI CE
EVI CE
the
, check the protocol (update log) for the
PORTAL
corresponding machine.
The protocol contains important information on the update
procedure.
Example of protocol content after a successful update:
> <BEGIN>: 1532699807
> <actSW>: Fw 6.0.41.181 Release
> <actBL>: Bl 9.2
> <actDOD>: FOTA Test V4
> File Size: 435908
> Received rmware le
> Received rmware le correct
> <newSW>: Fw 6.1.0.0 Release
38
TFX INSTALLATION AND OPERATION MANUAL
L
eld, the message
OG
appears when the
U CC ESSFULLY
tform.
DATA PLA
> D
F
area of
OWNLOA D
ILES
> <newBL>: Bl 9.2
> <newDOD>: FOTA Test V4
> <END>: 1532700197
Example of protocol content after a failed update:
> <BEGIN>: 1534330801
> <actSW>: Fw 6.1.0.0 Release
> <actBL>: Bl 9.1
> <actDOD>: CANlink mobile 3337 Demo V1
> File Size: 424836
> Received rmware le
> Update aborted: error le access
> <newSW>: Fw 6.1.0.0 Release
> <newBL>: Bl 9.1
> <newDOD>: CANlink mobile 3337 Demo V1
> <END>: 1534331309
See Service and support for additional questions.

5.9.2 CAN

In order to load the rmware update (*.FWBIN) to the
device via the CAN interface, the device must be connected
to a PC via a CAN-USB connection. PROEMION Firmware
Programmer must be installed on the PC and the rmware
update must be stored.
1. Connect the device to a PC. See chapter Connecting
the device to the PC
2. Start the
Firmware Programmer software.
PROEMION
3. In the menu, click on
to the storage path for the rmware update (*.
4. Select the rmware update (*.
O
button.
PEN
5. Click in the menu on
C
S
OMMUNI CATION
ETTINGS
The C
S
OMMUNI CATION
ETTINGS
6. In the C
OMMUNI CATION
D
list and select the device
EVI CE
7. In the USB eld, go to the
select the port you require.
8. Click on the O
-C
NLINE
6046279-001
March 2020
F
> O
C
+O and navigate
ILE
PEN
TRL
F
B
) and click on the
W
IN
O
> S
>
PTIONS
ETTINGS
.
window opens.
G
area, go to the
G
ATEWAY
TFX S
T
UPPORT
V
COM - P
IRTUAL
ORT
button.
HE CK
F
B
).
W
IN
ATEWAY
.
OOL
list and