Operation
DOWNLOADING AND DISPLAYING OR CONVERTING FILES
You can download data from the data platform and use
PROEMION Dashboard to display it or PROEMION
Converter to convert it.
PROEMION Dashboard can directly read the saved
log les (.clf).
With PROEMION Converter, you can convert the data into a
comma-separated text le (.csv) or provide the position data
for use in Google Earth or Google Maps (.kml).
You can nd a description of the log les (.clf) in the "clf.pdf"
le on the PROEMION Tools CD (path: CD_PROEMION_
Tools\Devices\Proemion\clf.pdf). The PROEMION Tools
CD also contains sample les and a Windows DLL for
converting CLF and CNT les (path: CD_PROEMION_Tools\
RMtools\Developer\CLF DLL Demo Projects\RMtools CLF
DLL Delphi Demo.zip). You can use this data to write your
own converter or import functions.
To nd out how to download data from the data
platform, ask your Eaton technical support about
the PROEMION Web Services API.

5.3 Real-time mode

In real-time mode, CAN messages are
transmitted bidirectionally.
CAN messages and GNSS data can be transmitted in close
to real-time.
Use DANFOSS Con gurator for the con guration. The basics
are described in Chapter Con guring the device.
NOTICE
Before you start a real-time session, check the device status
in the machine overview in the Portal. The device must be in
real-time mode.
The colored squares in the machine overview indicate the
current status:
Constant blue = device is passive in real-time mode
Flashing blue = device is connected to a real-time
client software
Grayed out = device is o ine
Constant green = device is in le transfer / logging mode
Click on the current status to change it.

5.3.1 Con guring real-time mode

1. Start the DANFOSS Con gurator software.
2. Choose F
> O
from the menu.
ILE
PEN
30
TFX INSTALLATION AND OPERATION MANUAL
3. Open the con guration le you want.
4. In the object dictionary group
on the variable
D
EVI CE
5. In the D
M
(C
EVI CE
ODE
6. Click the Save changes button to save
the con guration.
You have con gured the real-time mode.
NOTICE
Con guring the DEVICE-MODE variable during rst startup
of the device.
After manual switchover of the connection mode or after
an automatic switchover by a real-time client software, the
device remains in the mode last activated.
If required, con gure the automatic switchover of the
device. See chapter Con guring automatic switchover.
5.3.2 Creating a real-time connection and evaluating CAN
messages
For a real-time connection, you must log in to the Portal.
There you can download an installation-free version of
PROEMION Dashboard in order to evaluate your
CAN messages.

5.3.3 Setting a reception lter

You can lter CAN messages for transmission to the Data
platform. Set lters using
PROEMION Dashboard.
6046279-001
March 2020
D
V
EVI CE
ARIA B LES
M
(C
).
ODE
ONFIGURE D
) eld, enter the value 2.
ONFIGURE D
, click

Advertisement

Table of Contents
loading

This manual is also suitable for:

102ec77300a102ec77302a102ec77301a

Table of Contents