Contents 1 Warning signs in text .................... 7 Warning signs ......................7 2 About this document ..................... 9 General information....................9 Target groups ......................9 Symbols........................9 Associated documents....................9 3 Safety ..........................11 Proper use ......................11 Safety information....................12 Safety instructions for magnetic coupling systems..........13 4 Labelling ........................15 Type code .......................15...
Page 4
7.4.2 Disposing of the pump ................31 8 Installation, removal and connection ............33 Safety instruction on installation, removal and connection........33 Installation ......................33 Installing the pump ....................34 Protect the pump against soiling ................35 8.4.1 Connecting the pump to the pipe system...........35 8.4.2 Connecting the motor ................36 Removing the pump ....................
Page 5
12.2.1 ALP 0015-0020 Magnetic coupling - Maintenance kit........68 12.2.2 ALP 0030-0040 Magnetic coupling - Maintenance kit........69 12.2.3 ALP 0055-0085 Magnetic coupling - Maintenance kit........70 12.3 Flange gasket......................70 12.4 Tensioning element....................71 12.5 Valve body (cone)....................72 12.6 Cylindrical spring..................... 72 12.7 Containment can..................... 72 12.8 Screw plug for ALP magnetic coupling..............73 13 Appendix ........................75...
1 Warning signs in text 1.1 Warning signs Pay attention to the safety instructions in this manual. Below are definitions of the three grades of warning signs used in the text where there is a risk for injury to personnel. DANGER DANGER Indicates an imminently hazardous situation which, if not avoided, will result in...
Page 8
1 Warning signs in text 200007721-1-EN-GB...
2 About this document 2.1 General information The operating instructions form part of the pump or of the pump unit and must be kept for future reference. Further more please observe the associated documents. 2.2 Target groups Target group Tasks •...
Page 10
2 About this document 200007721-1-EN-GB...
3 Safety 3.1 Proper use • Use the pump solely for transporting lubricating liquids that are chemically neutral and that contain no gas or solid components. • Use the pump only within the performance limitations specified on the rating plate and in the "Technical data" section. In the case of operating data that does not agree with the specifications on the rating plate, please contact the manufacturer.
3 Safety 3.2 Safety information NOTE The following general safety instructions must be observed. • No liability is accepted for damage arising through non-observance of the operating instructions. • Read the operating instructions carefully and observe them. • The operator-owner is responsible for the observance of the operating instructions.
Safety 3 3.3 Safety instructions for magnetic coupling systems. Magnetic fields from magnetic coupling systems (MCS) can influence the function and operational safety of electrical and electronic devices. NOTE The following safety instructions must be observed. Additional safety instructions for magnetic coupling systems. •...
4 Labelling 4.1 Type code 1. Model 2. Size 3. Shaft seal 4. Overflow valve 5. Completion 6. Motor size Figure 1: Type code Table 1: Type code Pos. Designation Type Model Single pump. Size Corresponds to flow rate in [l/min] at 1 450 min Mechanical seal of hard material.
4 Labelling 4.2 Communication plate 1. Pump type 2. Serial number 3. Year of contructions 4. Item number 5. Temperature max. 6. Differential pressure max. Figure 2: Rating plate 200007721-1-EN-GB...
NPSH value [mWC] at Rota- Size Viscosity NPSH value [mWC] at Rota- tion speed [min tion speed [min 1450 1750 2900 3500 1450 1750 2900 3500 ALP 15 ALP 55 ALP 20 ALP 75 ALP 30 ALP 85 ALP 40 200007721-1-EN-GB...
5 Technical data 5.4 Dimensions Table 5: Dimensions ALP pump Size Pump [mm] Shaft end [mm] 15 - 20 30 - 40 55 - 85 Table 6: Dimension pump unit with magnetic coupling Size Motor Magnet pow- Pump unit [mm] size er [Nm] LG**...
6 Function description 6.1 Structure Figure 3: Structure of ALP pump Figure 4: Structure of ALP pump with magnetic coupling and motor 1. Overflow valve 5. Balancing cylinder 9. Pump 13. Coupling hub 2. Screw plug 6. Ball bearing 10. Pump bracket 14.
6 Function description 6.1.1 Standard direction of rotation Clockwise, as seen from the drive; marked on the housing by two arrows. Refer to Structure on page 25. 6.1.2 Flow direction Marked on the housing by two arrows. Refer to Structure on page 25.
7 Transportation, Storage and Disposal 7.1 Unpacking and checking the state of delivery 1. Upon delivery unpack the pump/pump unit and check for transport damage. 2. Report any transport damage immediately to the manufacturer. 3. Dispose of packing materials in accordance with the locally applicable regulations.
7 Transportation, Storage and Disposal 1. Pump: Depending on the locally applicable regulations, the pump can be transported either manually or by using suitable hoisting equipment. 2. Pump unit: Attach the hoisting equipment to the pump unit, and lift the pump unit.
Transportation, Storage and Disposal 7 7.4 Preservation Preservation has to be carried out in the following cases: • For standard delivery : for storage periods exceeding six weeks and in case of adverse storage conditions such as high humidity, salty air,etc. •...
7 Transportation, Storage and Disposal 7.4.1 Removing the preservation Recommendations: • Solvent • Steam-jet cleaning device with wax-dissolving additives WARNING Risk of injury through emitted preservative oil. • Wear protective clothing during all the work. • Remove the blind flange with caution to relieve any pressure inside the pump.
Transportation, Storage and Disposal 7 7.4.2 Disposing of the pump Recommendations: • Solvents or industrial cleaners suitable for the pumped liquid. WARNING Danger of poisoning and damage to the environment from the pumped liquid. • Wear protective clothing during all the work. •...
Page 32
7 Transportation, Storage and Disposal 200007721-1-EN-GB...
8 Installation, removal and connection 8.1 Safety instruction on installation, removal and connection NOTE The following safety instruction must be observed during installation, removal and connection work. • There is a risk of death for people with pacemakers • Under no circumstances may persons with pacemakers perform installation, removal or connection work.
8 Installation, removal and connection 8.3 Installing the pump Screw pumps can be operated in any installation position. However, we recommend that the pump should not be mounted above the motor since pumped liquid could enter the motor should a leak occur. Figure 7: Model ALP Horizontal mounting Figure 6: Model ALP vertical mounting Prerequisite:...
Installation, removal and connection 8 8.4 Protect the pump against soiling CAUTION Damage through impurities in the pipe system. • During welding work attach protective covers to the connecting flanges. • Ensure when welding that welding beads and abrasive dust cannot get into the pipe system and the pump.
8 Installation, removal and connection 1. Turn the pump shaft or the fan impeller of the motor. This tests that the pump runs smoothly. If the pump cannot be turned by hand, remedy the fault before installing the pump. 2. During welding work attach protective covers to the connecting flanges. 3.
Installation, removal and connection 8 8.5 Removing the pump Recommendations: • Vessels for leaking pumped liquid DANGER Risk of death resulting from electric shock. • Ensure that the power supply is disconnected. • The motor may only be separated from the power supply by an authorized electrician.
Page 38
8 Installation, removal and connection 200007721-1-EN-GB...
9 Operation 9.1 Commissioning CAUTION The following safety instruction must be observed during commissioning. • There is a risk of death for people with pacemakers • Under no circumstances may persons with pacemakers perform commissioning work. CAUTION The following instructions must always be observed. The pump may only be commissioned by authorized qualified personnel.
9 Operation 9.2 Cleaning the pipe system To protect the pump against soiling the complete pipe system has to be cleaned carefully before initial commissioning of the pump. If the pipe system is to be rinsed using the pump, an additional commissioning filter has to be installed before the pump.
Operation 9 9.3 Filling the pump There are two possible ways to fill the pump: 1. Pumped liquid already exists at the suction or pressure side: filling via suction or pressure connection. Figure 10: Filling the pump 2. There is no pumped liquid at the suction or pressure side: filling via the vent hole.
9 Operation 9.4 Filling the pump via the suction or pressure connection WARNING Danger of injury or poisoning through dangerous pumped liquids. Collect the emitted pumped liquid safely and dispose of it in an environmentally compatible manner. Open the vent hole 3 so that the air can escape during the filling process.
Operation 9 9.5 Checking direction of rotation The direction of rotation and the flow direction are indicated by arrows on the pump. The direction of rotation of the motor gives the direction of rotation of the pump. That is to say, the fan impeller of the motor must rotate in the direction in which the arrow on the pump is pointing to indicate direction of rotation.
9 Operation 9.6 Commissioning the pump Prerequisites: • Pump set up and mounted correctly. • Motor connected correctly. • Pipe system is free of contamination. • Commissioning filter mounted, if the pipe system is to be cleaned with the pump. •...
Operation 9 9.7 Taking pump out of operation WARNING Risk of injury or poisoning through emitted pumped liquid. • Wear protective clothing during all the work. • Collect the emitted pumped liquid safely and dispose of it in an environmentally compatible manner. •...
9 Operation 9.8 Recommissioning the pump Carry out all the steps as for the commissioning process. Refer to Commissioning on page 39. 200007721-1-EN-GB...
10 Maintenance 10.1 Safety instructions on maintenance and repairs DANGER There is a risk of death for people with pacemakers. The following safety instructions must be observed during all work: • Under no circumstances may persons with pacemakers perform maintenance or repair work. •...
10 Maintenance 10.2 Required maintenance The service life of the pump depends to a great extent on the operating conditions. If the operating limits are observed, refer to Technical data on page 17;the pump has a service life of many years. Signs of progressive wear of individual pump elements: Table 15: Check table for required maintenance Finding...
Maintenance 10 10.5 Replacing the magnetic coupling Removing the magnetic coupling 10.5.1 Dismantling the outer rotor Figure 12: Outer rotor disman- tling Ref. Description Ref. Description Ref. Description Pump Outer rotor 914.3 Socket screw Coupling hub Motor 914.5 Socket screw Pump bracket Threaded pin Mounting lever...
Page 50
10 Maintenance Before dismantling close the suction and pressure connection of the pump with protective covers . Loosen the connecting screws 914.3 between the motor 529 and pump bracket 180 and lift the pump with pump bracket from the motor. Loosen the threaded pin 884.
Page 52
10 Maintenance Loosen the socket screws 914.6 between the centring flange 110 and pump. Remove the containment can. To replace the inner rotor 518, insert two anti- rotation screws B into the empty threaded holes of the tensioning element to prevent rotation.
Maintenance 10 10.6 Installing the magnetic coupling 10.6.1 Mounting the inner rotor Figure 14: Sectional view magnetic coupling Ref. Description Ref. Description Ref. Description Containment can Pump bracket 739.2 O-ring Distance sleeve Inner rotor 914.2 Socket screws Centring flange Tensioning element 914.6 Socket screws 200007721-1-EN-GB...
Page 54
10 Maintenance Carefully clean the sealing surfaces. Clean and slightly grease the O-ring. Insert the O- ring 739.2 and slide the distance sleeve 040 onto the pump shaft. Clean the contact surfaces of the inner rotor 518 carefully. Oil the tensioning element 585 slightly.
Page 55
Maintenance 10 Check the position of the tensioning element: the tensioning element has to lie on the distance sleeve and inner rotor. Otherwise loosen the screws again and re- align the tensioning element. If the position is correct, first tighten the screws of the tensioning element with half the tightening torque crosswise.
Page 56
10 Maintenance Place the pump bracket 180 on the pump and tighten the socket screws 914.2 . 200007721-1-EN-GB...
Maintenance 10 10.6.2 Mounting the outer rotor Figure 15: Ref. Description Ref. Description Ref. Description Pump Outer rotor 914.5 Socket screw Coupling hub Motor 914.3 Socket screw Pump bracket Threaded pin Carefully clean the outer rotor 515 with compressed air. Tighten the connecting screws 914.5 of the outer rotor and coupling hub 053 with torque.
Page 58
10 Maintenance The shaft end of the motor must be flush with the front surface of the coupling hub. Place the pump with pump bracket on the motor. Do not use force and ensure that the outer rotor does not strike the containment can. Tighten the connecting screws 914.3 of the motor and pump bracket.
Maintenance 10 10.7 Replacing the ball bearing 10.7.1 Removing the ball bearing Figure 16: Ref. Description Ref. Description Ref. Description 056(*) Supporting ring Circlip Disassembly tool 165.1 Screw plug Ball bearing Open-end wrench 471.2 Circlip 868* Supporting ring Extractor * Only for sizes 100 - 115. Recommendations: •...
Page 60
10 Maintenance Screw in the disassembly tool A by using the open-end wrench B. The main screw will be pressed out of the pump housing. Remove the main screw from the pump housing. Remove the circlip 471.2 and supporting ring 056.
Maintenance 10 10.7.2 Installing the ball bearing Figure 17: Ball bearing installa- tion Ref. Description Ref. Description Supporting ring Circlip 165.1 Screw plug Ball bearing Circlip 868* Supporting ring * Only for sizes 100 - 115. Clean the fitting surfaces and the main screw. Grease the main screw slightly.
11 Troubleshooting 11.1 Possible faults Faults can have different causes. The following tables list the symptoms of a fault, the possible causes and measures for elimination. Fault Cause/Remedy • No pump suction 1, 2, 3, 4, 5, 6, 7, 8, 28 •...
11 Troubleshooting 11.2 Troubleshooting Table 16: Fault table Cause Remedy - Check shut-off devices in the suction pipe and open them, Pump suction pipe closed. if necessary. Suction valve or pipe obstructed. - Check the suction valve and pipe for clear passage. - Check suction pipe or shaft seal for leaks.
Page 65
Troubleshooting 11 Cause Remedy Advanced wear of rotating pump - Check screw set and housing and replace if necessary. components. - Support the weight of the piping. Pump distorted. - Loosen pipe connections and mount stress-free; refer to Installation on page 33. - Provide a flexible bearing arrangement -or Resonance in the system.
12 Spare Parts 12.2 ALP Magnetic coupling - Maintenance kit 12.2.1 ALP 0015-0020 Magnetic coupling - Maintenance kit Figure 19: ALP 0015-0020 Magnetic coupling – Maintenance kit 9014380 80 Table 17: ALP-0015-0020, Magnetic coupling, Size 75, Nm 10, IEC 80+90 ALP 0015-0020 Magnetic coupling Denomination Qty.
Spare Parts 12 ALP 0015, ALP 0020 2x 1764629 01 D: 25 mm ALP 0030, ALP 0040 1x 1764629-01 D: 25 mm 1x 1764628-01 D: 40 mm ALP 0050, ALP 0075, ALP 0085 2x 1764628-01 D: 40 mm 12.4 Tensioning element Tensioning element, Pos.
12 Spare Parts 12.5 Valve body (cone) Valve body (cone), Pos. 305 Pump type Part no. ALP 0015-0020, 901287701 Magnetic coupling ALP 0030-0040, ALP 0055-0085, 901287702 Magnetic coupling 12.6 Cylindrical spring Cylindrical spring, Pos. 501 Pump type Part no. ALP 0015–0020, 9014370 02 Magnetic coupling ALP 0030–0085,...
Spare Parts 12 12.8 Screw plug for ALP magnetic coupling Figure 22: Srew plug Table 20: Screw plug for ALP magnetic coupling Pump type ALP Screw plug Part no. Pos. no. DVV 36 9046911 01 165.1 0015 0020 DVV 36 9046911 02 165.2 DVV 36...
Need help?
Do you have a question about the ALP 15 and is the answer not in the manual?