4.3. Cables

4.3.1. Start Cable / Main Plug Connector
The pin assignment and wire colours of the main plug connector cable delivered with the device is provided here.
Figure 6. Start Cable / Main Plug Connector
Figure 7. Main plug connector Pin Layout
Table 4. Cable for main plug connector
Pi
Designation
Color
n
1
VCC
Red
2
DOUT 3
Dark Grey
3
AIN 2 / DIN 3
Light Grey
4
DIN 2-N/AIN1
Green-White Digital input, channel 2, Negative input, Analog input, channel 1, Input range:
5
DIN 1
Yellow
6
INPUT 6
Blue-White
7
GND
Black
8
DOUT 1
Orange-
White
9
DOUT 2
Dark Purple Digital output, channel 2. Open collector output. Max. 0.5 A DC
10 1WIRE
Blue
POWER
11 1WIRE DATA
Green
12 INPUT 5
Yellow-White RX EXT (LVCAN - RX)
Basic Tracker Device Manual
Description
Power supply (10...30 V DC)
Digital output, channel 3. Open collector output. Max. 0.5 A DC
Analog input, channel 2. Input range: 0...30 V DC / Digital input, channel 3
0...30 V DC
"Working" signal (e.g. TERMINAL 15 / IGNITION)
TX EXT (LVCAN – TX)
Ground
Digital output, channel 1. Open collector output. Max. 0.5 A DC
+3.8 V output for 1–Wire devices
Data for 1–Wire devices

Advertisement