KSB Calio SI Dual Installation & Operating Manual page 39

Circulator for oems
Hide thumbs Also See for Calio SI Dual:
Table of Contents

Advertisement

7 Operation
7.2.6.3 Operation controlled by analog signal 0 - 10 V
E
D
C
0
1
2
3
Fig. 15: Operation controlled by analog signal 0 - 10 V
A Speed [rpm]
B Voltage of input signal
C Pump OFF
D Minimum speed 800 rpm
E Maximum speed [rpm]
Table 23: Speeds depending on the size
Size
15-50-130
25-50-130
25-50-180
15-70-130
25-70-130
25-70-180
15-80-130
25-80-130
25-80-180
30-80-180
Calio SI Dual / Calio SI Therm
4
5
6
7
8
B [V DC]
Speed
Minimum
[rpm]
800
800
800
800
800
800
800
800
800
800
9
10
11
12
Maximum
[rpm]
3080
3080
3080
3650
3650
3650
4000
4000
4000
4000
39 of 50