A. WHITE BALANCE ADJUSTMENT.
White Balance Adjustment / Gamma Adjustment
NO.
ITEM
a)
Setting
b)
Auto
Adjustment
[command]
Adjustment
Mode
KRSW0001
KKT10037
Setting
OSDS0001
SBSL0016
Multi point
adj. Mode
MSET0000
WBI20255
Adj Point 2
WBI20229
MG2G****
MG2B****
MG2R****
Adj Point 1
WBI10040
MG1G****
MG1B****
MG1R****
Set
Max.Level
MGMG****
MGMR****
MGMB****
Write
MSET0003
CONDITION
For the details of white balance adjustment procedure, please refer to white balance
adjustment spec for Kameyama model.
AV Mode : DYNAMIC
Backlight : MAX
1. Confirm the set condition.
Set the luminance
2. Connect the white balance jig.
meter on the centre
i. 3.5mm H/P Jack. ( 4 Pole Pin)
ii. RS-232 Cross cable ( 2 pcs ) + Convert wire from RS-232 D-Sub ( 9 pin to 3.5mm
of the screen
H/P Jack ( 4 Pole Pin ).
3. Through RS-232C command, adjustment mode screen is displayed.
Panel Contrast
R/G/B_MAX
Initial setting
R/G/B_HIGH
R/G/B_LOW
(1)
Measurement
MAX Brightness
(2)
Set
MIN Brightness
(3)
Measurement
HIGH Brightness
(4)
Measurement
LOW Brightness
(5)
Calculation
H
(6)
Calculation
L
HIGH luminance ( =2.2)
(7)
Calculation
(8)
Calculation
Initial setting of
R/G/B_HIGH
(9)
Set
Initial setting of
R/G/B_HIGH
(10) Original WB adjustment is performed (HIGH)
Set the specified gradation for point 2, fix the
most
faint
colour to get reference value,
adjust others 2 colours to minus adjustment
for reference value of point 2.
(11) Measurement
HIGH Brightness
(Set)
R_HIGH= G_HIGH
G_HIGH= G_HIGH
B_HIGH= G_HIGH
(12) Calculation
MAX luminance after WB
ADJ set to =2.2 (L
(13) Set
R/G/B_MAX
LOW luminance ( =2.2)
(14) Calculation
(15) Calculation
Initial setting of
R/G/B_LOW
(16) Set Initial setting of R/G/B_LOW
(17) Original WB adjustment is performed (LOW).
Adjust RB to the reference value of point 1.
(18) Adjusted value is writing at [command]
MSET0003
PROCEDURE
C
= 4000:1
nt
WB
= 4080
MAX
WB
H
= 3664/4080
WB
L
= 640/4080
L
=305.7 cd/m²
max
L
min
= L
max
/C
nt
= 0.102
L
=235.1 cd/m²
XH
L
=2.06 cd/m²
XL
H =LOG((L
-L
min
XH
L =LOG((L
-L
min
XL
L
=(L
-L
) x (WB
max
min
H22
WB
=WB
X ((L
HX
MAX
R_HIGH=WB
'=3703
HX
G_HIGH=WB
'=3703
HX
B_HIGH=WB
'=3703
HX
R_HIGH=3702
G_HIGH=3641
B_HIGH=3703
R_HIGH=3641
G_HIGH=3641
B_HIGH=3641
L
=L
/((W
/WB
B
XMX
XHG
H
R_MAX=G_MAX*(R_HIGH/G_HIGH)=4078
)
XHG
G_MAX=WB
X ((L
MAX
B_MAX=G_MAX*(B_HIGH/G_HIGH)=4078
L
=(L
-L
) x (WB
min
XLX
XMX
WB
=WB
X ((L
LX
MAX
R_LOW=WBXLX=901
G_LOW=WBXLX=901
B_LOW=WBXLX=901
R_LOW= 921
G_LOW=901
B_LOW=971
5 – 5
Example for adjustment method
(be careful of INT setting)
)/(L
-L
))/LOG(WB
/WB
)= 2.44
max
min
H
MAX
) /(L
-L
))/LOG(WB
/WB
max
min
L
MAX
/WB
)^2.2+L
=241.31
min
H
MAX
-L
)/(L
-L
))^(1/H )=3703
min
max
min
H22
RESULT
L
231.3
=
XHG
)^2.2)=293.04
MAX
-L
)/(L
-L
))^(1/H )=4010
min
max
min
XMX
/WB
)^2.2+L
=5.08
min
L
MAX
-L
)/(L
-L
))^(1/L )=901
min
max
min
XLX
RESULT
)=2.73