Installation

Unpacking
Immediately after unpacking, check for possible shipping damage. If the tilting braising pan is found to be
damaged, save the packaging material and contact the carrier within 15 days of delivery.
Before installing, verify that the electrical service agrees with the specifications on the rating plate located
on the left side panel as you face the front of the braising pan. If the supply and equipment requirements do
not agree, contact your dealer or Crown Food Service Equipment Ltd.
Units equipped with a three-prong (grounding) plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong
from this plug. (120 volt units only).
Installation Instructions
1. Position appliance on counter allowing sufficient rear clearance from wall to tilt freely and completely without obstruction.
2. Mark four corner locations of appliance base, as shown below.
3. Remove appliance from counter and locate position of four holes as per drawing below. Drill four 7/16" diameter holes.
4. Apply a continuous bead of Silastic or other equivalent sealant along the complete perimeter edge of the appliance base.
5. Use 5/16-18 Hex Cap Screws with suitable flat washer to bolt down. Screw length must be 1-1/4 long plus counter top
thickness.
6. Wipe off excess sealant.
7. A Control Box with power supply equivalent to Electrical Rating of appliance should be located conveniently nearby.
8. A waterproof electrical connection for power supply to console housing must be provided.
9. Ground appliance to terminal provided inside console housing.
10. Turn power ON and check for proper operation.
INSTALLATION & OPERATION MANUAL 10088 REV 2 (10/22)