INSTALLATION
3
Click OK to print the template.
4
Measure the printed template with a ruler to ensure that it is the
correct size.
5
Use a center punch to mark the center of the holes on the wall.
6
On the wall, locate the marks for the mounting holes you just
made.
WARNING!
Before drilling holes, check the structure for potential
damage to water, gas, or electric lines.
7
Drill the holes to a depth of at least 3.8 cm (1½ inches).
8
If necessary, seat an anchor in each hole. Use M5 x 38 mm
(#10-16 x 1½ inch) screws with a flat underside and maximum
screw head diameter of 10.5 mm to mount the unit.
9
Using a screwdriver, turn each screw until part of it protrudes
from the wall, as shown:
!
There must be 4.0 mm (.16 inches) between the wall and the
underside of the screw head.
!
The maximum distance from the wall to the top of the screw
head is 7.6 mm (.3 in).
7.6 mm (.3 inches)
maximum
4.0 mm
10 Remove the front two plastic feet, nearest to the LED panel, from
the bottom of the unit to uncover the keyholes.
11 Place the unit so the keyholes are above the mounting screws.
12 Slide the Wireless Ethernet Bridge down until it stops against the
top of the keyhole opening.
13 Follow the procedures in "Electrical Connection to Wireless
Ethernet Bridge" located later in this section to connect the unit.