Summary of Contents for STRIDE SIO-MB08THMS

  • Page 1 ® Field I/O SIO-MB08THMS USER GUIDE Temperature Input Module: thermocouple, 8-channel in Manual Number: SIO-MB08THMS-UG...
  • Page 2: Register Addresses

    • A maximum of 64 registers can be written by Modbus function code 16 (see “Supported modbus functions codes”). • A maximum of 64 coils can be written by Modbus function code 15 (see “Supported modbus functions codes”). SIO-MB08THMS User Guide, 1st Edition...
  • Page 3 Stride Field I/O PRODUCT LABEL AND WIRING DIAGRAM Terminal block pinouts and wiring diagrams are printed on the side of the module, as shown below. SIO-MB08THMS User Guide, 1st Edition...
  • Page 4 Default: Tc K (0505 Hex) TC T TC B 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 TC E Description Input Type #3 Input Type #2 TC N SIO-MB08THMS User Guide, 1st Edition...
  • Page 5 When a break condition is detected (e.g., broken sensor, disconnected cable, or over temperature) the bit corresponding to the channel is set to 1. Input Description Break input #7 Break input #6 Break input #5 Break input #4 Break input #3 Break input #2 Break input #1 Break input #0 SIO-MB08THMS User Guide, 1st Edition...
  • Page 6 These registers contain the offset values for each input. The values are expressed in cents of mV for mV input and tenths of °C for Tc input. The register format is a 16 bit unsigned integer. SIO-MB08THMS User Guide, 1st Edition...
  • Page 7 The device interface includes five configuration categories, as shown by the navigation menu on the left of the screen on the next page. Hovering over a navigation button will display a tooltip to describe the selection. SIO-MB08THMS User Guide, 1st Edition...
  • Page 8 Click Save to apply and store the modified parameters. Wait for the device to reset. After modifying the network settings you will need to use the updated IP address to connect to the device, and may need to change the subnet mask on your PC. SIO-MB08THMS User Guide, 1st Edition...
  • Page 9: System Configuration

    (0 = power cycle has not occurred ; 1 = power cycle has occurred ). Click Save to apply and store the modified parameters. To read the parameters from the device click Refresh. SIO-MB08THMS User Guide, 1st Edition...
  • Page 10 • Firmware Version: shows the firmware version loaded on the device. • WebPage Version: shows the version of the web-based user interface loaded on the device. Do not disconnect power from the device during the upgrade process. SIO-MB08THMS User Guide, 1st Edition...
  • Page 11 Set the user name and password. • Username: set the user name to access the device. Default “admin”. • Password: set the password to access the device. Default “password”. Click Save to apply and store the modified parameters. SIO-MB08THMS User Guide, 1st Edition...
  • Page 12: Analog Input

    • Offset: sets an offset value to be added to the raw sensor reading to calibrate the sensor. • Set Same Input: sets all channels to the input type selected for the first channel (Analog In 0). Click Save to apply and save all changes on the page. SIO-MB08THMS User Guide, 1st Edition...
  • Page 13 To exit from the alarm condition, send any command to the device and reset the “Watchdog Event” coil. NOTE: When the device is switched off the state of the “Watchdog Enable” bit remains stored in EEPROM. SIO-MB08THMS User Guide, 1st Edition...