What to Do?

If there is no water due to a power outage or water failure

■ If a power outage occurs
Press the button on the fl ush panel to fl ush.
■ If a water outage occurs
1
Use a bucket to fl ush water.
If the water level is low after fl ushing,
2
add more water.
(Prevents odors.)
Attention!
●If there is a water supply failure, set the auto bowl unit cleaning to "OFF".
●When the water supply is restored, be sure to perform a fl ush.
(To prevent waste from remaining in the drain pipe.)

If you cannot operate with the remote control

■ Operation is also possible using the
buttons on the control panel.
Control panel
■ Replacing the batteries
1
Press [POWER ON/OFF] on the control panel.
The POWER LED goes off.
2
Remove the remote control from the hanger.
(Page 14)
3
Open the cover and replace the AA
batteries.
(Page 14)
4
Mount the remote control in the hanger.
5
Press [POWER ON/OFF] on the control panel.
The POWER LED lights up.
52
Flush panel
Large bucket
Pour strongly,
aiming at the center
of the bowl unit.
Newspaper, dustcloth, etc.
■ If the low battery
Low battery warning LED
warning LED is
fl ashing, replace the
batteries.
POWER LED
Control panel
What to Do?
When the ambient temperature is likely to drop to 0°C or lower, take measures to prevent freezing.
Attention!
● When the ambient temperature is likely to drop to 0°C or lower, do not use the energy saver feature. (May damage the product.)
● Warm the bathroom or take measures against freeze so that the ambient temperature does not drop below 0°C.
●Before starting work, set "AUTO FLUSH" (Page 42) and "AUTO OPEN/CLOSE" (Page 44) to "OFF".
Anti freezing
■ How to drain the water
Remove the side-panel (left)
1
and close the shutoff valve.
(Page 15,Page 55)
Drain the pipe.
2
(1) Extend the wand.
Operate with the buttons on the back
side of the remote control.
1.
Press [MENU].
Use
to select
2.
[MANUAL CLEANING].
3.
Press [
ENTER].
Use
to select [WAND
CLEANING ON/OFF].
Press [
ENTER] to extend
the wand.
Hold the wand in the extended
position until no more water
comes from around the wand.
Press [
ENTER] again to
retract the wand.
(Release the pressure from
the water supply pipe.)
(2) Unplug the power plug.
(Page 15)
Switch the breaker on the distribution
board to OFF. (UK)
(3) Remove the cover and water fi lter
drain valve.
Cover
Water filter
drain valve

Freeze Damage Prevention

(4) After draining the water, install the
water fi lter drain valve and cover.
Insert the water fi lter drain valve and
use a fl at-head screwdriver to tighten
it securely.
Cover
(5) Insert the power plug.
(Page 15)
Switch the breaker on the distribution
board to ON. (UK)
Check that the POWER LED on
3
the main display is lit up.
(Page 15)
Set the toilet seat temperature
4
to "High".
(Page 24)
(To maintain the temperature.)
When fi nished, close the toilet seat and toilet lid.
Reinstall the side-panel (left).
5
(Page 15)
■ To use the NEOREST again
The water needs to be replenished. (Page 54)