one of the units' power is disconnected.
5.
Each lighting unit needs to have an address set to receive the data sent by the controller. The
address number is between 0-511 (usually 0 & 1 are equal to 1).
6. The end of the DMX 512 system should be terminated to reduce signal errors.
7.
3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin 4/Pin 5: Not used.

4.2 Address Setting

If you use a universal DMX controller to control the units, you have to set DMX address from 1 to
512 so that the units can receive DMX signal.
Press MENU button to enter menu mode, select DMX Functions, press the ENTER button to
confirm, use the UP/DOWN button to select DMX Address, press the ENTER button to confirm,
the present address will blink on the display, use the UP/DOWN button to adjust the address from
001 to 512, and press the ENTER button to store. Press the MENU button back to the last menu or
let the unit idle 7 seconds to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units :
Channel mode
14 channels
Unit 1
Unit 2
Address
Address
1
14D
Unit 3
Address
15
29
Unit 4
Address
43