Advertisement

Quick Links

DIALighting
IW19-10 ZOOM
User Manual
Please read the instruction carefully before use
0D

Advertisement

Table of Contents
loading

Summary of Contents for Dialighting IW19-10 ZOOM

  • Page 1 DIALighting IW19-10 ZOOM User Manual Please read the instruction carefully before use...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. Safety Instructions.....................2 2. Technical Specifications.....................3 3. How To Set The Unit....................4 3.1 Control Panel.......................4 3.2 Main Function......................5 3.3 Home Position Adjust..................12 4. Control By Universal DMX Controller..............13 4.1 DMX 512 Connection..................13 4.2 Address Setting....................14 4.3 DMX 512 Configuration..................15 5.
  • Page 3: Safety Instructions

     Before operating, ensure that the voltage and frequency of power supply match the power requirements of the unit.  It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.  The unit is for indoor use only. Use only in a dry location. ...
  • Page 4: Technical Specifications

    DO NOT touch any wire during operation as high voltage may cause electric shock. Warning:  To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture.  The housing and lenses must be replaced if they are visibly damaged. Caution: There are no user serviceable parts inside the unit.
  • Page 5: How To Set The Unit

    5 Fixture Max. (130V, 60Hz)  Beam Angel: 10° ~ 60°  LED Source: 19 × 10W RGBW LED  Weight: 9.2Kgs  Dimension: 325 × 188 × 395mm 3. How To Set The Unit 3.1 Control Panel 1. Display: Shows the various menus and the selected functions LED: 2.
  • Page 6: Main Function

    ENTER To confirm the selected functions 5. DMX input: DMX512 link, use 5-pin XLR cable to link the unit and DMX controller 6. DMX input: DMX512 link, use 3-pin XLR cable to link the unit and DMX controller 7. DMX output: DMX512 link, use 5-pin XLR cable to link the next unit 8.
  • Page 8 DMX Functions Enter MENU mode, select DMX Functions, press the ENTER button to confirm, use the UP/DOWN button to select DMX Address or View DMX Value. DMX Address To select DMX Address, press the ENTER button to show the DMX ADDRESS on the display. Use the UP/DOWN button to adjust the address from 001 to 512, press the ENTER button to setup.
  • Page 9 MENU button back to the last menu or let the unit idle one minute to exit menu mode. BL.O. P/T Moving To select BL.O. P/T Moving, press the ENTER button to show the BLACKOUT WHILE PAN/TILT MOVING on the display, use the UP/DOWN button to select No (normal while pan/tilt moving) or Yes (blackout while pan/tilt moving), press the ENTER button to setup.
  • Page 10 Linear: The increase in light intensity appears to be linear as DMX value is increased. Square Law: Light intensity control is finer at low levels and coarser at high levels. Inverse Square Law: Light intensity control is coarser at low levels and finger at high levels. S-cure: Light intensity control is finger at low levels and high levels and coarser at medium levels.
  • Page 11 Temperature Unit To Select Temperature Unit, press the ENTER button to show the TEMPERATURE UNIT on the display. Use the UP/DOWN button to select ℃ or ℉, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode. Display Warning To select Display Warning, press the ENTER button to show the DISPLAY WARNING on the display.
  • Page 12 display. Press the ENTER button, the fixture working hours will show on the display. Press the MENU button to exit. Lamp On time To select Lamp On time, press the ENTER button to show the LAMP ON TIME on the display. Press the ENTER button to confirm, then use the UP/DOWN button to select Exit or Reset Time, press the ENTER button to store.
  • Page 13: Home Position Adjust

    Enter MENU mode, select Special Functions, press the ENTER button to confirm, use the UP/DOWN button to select Fixture Maintenance or Factory Setting. Fixture Maintenance To select Fixture Maintenance, press the ENTER button to show the FIXTURE MAINTENANCE on the display. Use the UP/DOWN button to select Interval or Remain Time. Interval To select Interval, press the ENTER button to confirm, the interval time will be shown on the display.
  • Page 14: Control By Universal Dmx Controller

    second or wait for about one minute to exit the menu mode. 4. Control By Universal DMX Controller 4.1 DMX 512 Connection 1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable. At last unit, the DMX cable has to be terminated with a terminator.
  • Page 15: Address Setting

    one of the units’ power is disconnected. Each lighting unit needs to have an address set to receive the data sent by the controller. The address number is between 0-511 (usually 0 & 1 are equal to 1). 6. The end of the DMX 512 system should be terminated to reduce signal errors. 3 pin XLR connectors are more popular than 5 pin XLR.
  • Page 16: Dmx 512 Configuration

    4.3 DMX 512 Configuration 14 channels mode:...
  • Page 17: Troubleshooting

    5. Troubleshooting Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting: A. The unit does not work, no light and the fan does not work Check the connection of power and main fuse. Measure the mains voltage on the main connector.
  • Page 18 Clean the external optics at least every 30 days.

Table of Contents