Idling Current Adjustment
Digital Voltmeter
V
V7001
N7007
N7007
V7001
1.
After DC Offset Voltage Adjustment is completed, adjust the Idling Current with the variable resistor V7001 and V7002
on the PCB P2(8U-110150-2).
2.
Turn off the power.
3.
"+" of Connect Digital Voltage is connected to the No. 1 pin and connected "–" to No. 2 pin of N7007.
4.
"+" of Connect Digital Voltage is connected to the No. 1 pin and connected "–" to No. 2 pin of N7008.
5.
Before turning on the power, V7001 and V7002 have been counter clockwise turned with the adjustment driver.
6.
Turn on the power, VOLUME is set as -∞.
7.
After 1 minutes, with seeing the digital voltage meter turn the variable resister clockwise slowly to adjust the idling
current.
Idling adjustment with V7001 (V7002).
Turn V7001 (V7002) clockwise to increase the idling current.
The adjustment value of idling current is
"10 mV(50 mA) ± 0.5 mV(2.5 mA)" each. f
8.
After 5 minutes, repeat the same procedure as 7. f
Turn V7001 (V7002) clockwise to increase the idling current.
The adjustment value of idling current is
"17 mV(85 mA) ± 0.5 mV(2.5 mA)" each. f
Adjustment is completed.
9.
Remove connection cable, attach the top cover.
NOTE : Idling current decreases with the temperature rise inside the unit, and it is set to "14 mV (70mA)" of setting value
in about 30 minutes after turn on the power. f