GENERAL SAFETY INFORMATION
Intended Use
The 3M
Full Facepiece Respirators 6000 Series are NIOSH approved and designed to help provide respiratory protection against certain airborne
TM
contaminants when used in accordance with all use instructions and limitations and applicable safety and health regulations.
The Full Facepiece 6000 Series meets the requirements of the ANSI Z87.1-2010 standard for face and eye protection. These products help provide
limited eye and face protection against flying particles.
This product contains no components made from natural rubber latex.
This respirator helps protect against certain airborne contaminants. Misuse may result in sickness or death. For correct use,
consult supervisor and User Instructions or call 3M in U.S.A. at 1-800-243-4630. In Canada, call Technical Service at
1-800-267-4414.
These User Instructions provide information about facepiece use only. Important information is provided in the User Instructions with each of the
air filtration/supplied air systems that are NIOSH certified to be used with the 3M™ Full Facepiece Respirator 6000 Series. Failure to follow User
Instructions for the air filtration/supplied air systems being used may result in sickness or death.
Do not clean respirator with solvents. Cleaning with solvents may degrade some respirator components and reduce respirator effectiveness.
Inspect all respirator components before each use to ensure proper operating conditions. Failure to do so may result in sickness or death.
When in supplied air mode, your employer must provide breathing air that meets at least the requirements of the specification for Grade D breathing
air, as described in the Compressed Gas Association Commodity Specification G-7.1-1997 in the United States. In Canada, breathing air systems must
be supplied with air, which meets at least the requirements of CSA Standard Z180.1. Failure to do so may result in sickness or death.
In Brazil breathing air systems must be supplied with air, which meets ANSI Z86.1-1989/CGA G-7.1, Grade D breathing air.
USE INSTRUCTIONS AND LIMITATIONS
Important
Before use, the wearer must read and understand these User Instructions. Keep these User Instructions for reference.
Use For
Respiratory protection from certain airborne contaminants according to United States NIOSH approvals, OSHA limitations, in Canada CSA standard
Z94.4 requirements, applicable local government regulations and 3M instructions. In Brazil follow the Respiratory Protection Program of the Ministry
of Labor.
Do Not Use For
Do not use for concentrations of contaminants which are immediately dangerous to life or health, are unknown or when concentrations exceed
10 times the permissible exposure limit (PEL) in air-purifying mode when qualitatively fit tested, 50 times the PEL in air purifying mode when
quantitatively fit tested, 1000 times the PEL when used in supplied air mode, or according to specific OSHA standards or applicable government
regulations, whichever is lower.
In Brazil, according to the Respiratory Protection Program of the Ministry of Labor, do not use quantitatively fit tested full facepiece respirators when
concentrations of contaminants are greater than 100 times the permissible exposure limit in air-purifying mode.
Use Instructions
1. Failure to follow all instructions and limitations on the use of this respirator and/or failure to wear this respirator during all times of exposure can
reduce respirator effectiveness and may result in sickness or death.
2. Before occupational use of this respirator a written respiratory protection program must be implemented meeting all the local government
requirements. In the United States employers must comply with OSHA 29 CFR 1910.134 which includes medical evaluation, training and fit testing
and applicable OSHA substance specific standards. In Canada, follow the recommendations of CSA Z94.4 and/or requirements of the applicable
jurisdiction, as appropriate. In Brazil, follow the Respiratory Protection Program of the Ministry of Labor requirements. When used in supplied air
mode, your employer must supply breathing air that meets at least the requirements of Grade D breathing air in Compressed Gas Association
Commodity Specifications G-7.1-1997. In Canada, breathing air systems must be supplied with air which meets at least the requirements of CSA
Standard Z180.1.
3. The airborne contaminants, which can be dangerous to your health, include those that are so small you may not be able to see or smell them.
4. If respirator becomes damaged; if you smell or taste contaminants; or if dizziness, irritation, or other distress occurs; leave contaminated area
immediately and repair or replace respirator, or contact supervisor.
W WARNING
1
(English)
User Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for 3M 6000 Series

  • Page 1 These User Instructions provide information about facepiece use only. Important information is provided in the User Instructions with each of the air filtration/supplied air systems that are NIOSH certified to be used with the 3M™ Full Facepiece Respirator 6000 Series. Failure to follow User Instructions for the air filtration/supplied air systems being used may result in sickness or death.
  • Page 2: Use Limitations

    S - Special or Critical User’s Instructions 3M™ Organic Vapor Service Life Indicator Cartridges (6001i and 60921i) are equipped with a passive 3M™ End of Service Life Indicator (ESLI). The indicator must be readily seen when wearing the respirator. If you cannot readily see the ESLI, use a mirror to observe the ESLI; rely on a co-worker who can see the ESLI;...
  • Page 3: List Of Products

    If the facepiece is to be used in air-purifying mode (without using the 3M™ Breathing Tubes SA-1600 or SA-2600), the inhalation valves must be replaced in the facepiece before use. Use of the 3M™ Nose Cup Assembly 6894 with the 3M™ Full Facepieces 6000 Series must be in accordance with the NIOSH approval for the system being used.
  • Page 4: Accessories And Parts

    **** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers. In Brazil, the 3M™ Filter 5935BR is approved as a NIOSH AS APPROVED and assumes full responsibility for its correctness. N95 filter and as a BMOL P3 filter. It can be used with the filter adaptor 603 and the filter retainer 501 on the 3M™ Half Facepiece 6000 Series. CAUTION Failure to properly dispose of spent cartridges, filters, or respirators contaminated by hazardous materials can result in personal exposures as well as environmental harm.
  • Page 5 ****AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers. 3M recommended for use against methylbromide or radioiodine up to 5 ppm with daily cartridge replacement. NOTE: Not NIOSH approved for use against methylbromide or radioiodine.
  • Page 6 3M recommended for ozone protection up to 10 times the OSHA PEL or applicable government occupational exposure limits, whichever is lower. NOTE: Not NIOSH approved for use against ozone. In Brazil, the 3M™ Filter 5935BR can be used with the Filter Adaptor 603 and the Filter Retainer 501 on the 3M™ Half Facepiece 6000 Series. ASSEMBLY INSTRUCTIONS NOTE: Make certain 3M™...
  • Page 7 Repeat for second filter. NOTE: The 3M™ Filter Adapter 502, once installed on a 3M™ Cartridge 6000 Series, is not to be removed or reused. Removal or reuse may result in leakage, overexposure, sickness or death.
  • Page 8: Fitting Instructions

    Assigned Protection Factor is 1000 times the PEL or other occupational exposure limit. W WARNING The 3M™ Dual Airline is NIOSH approved only with the 3M™ Nose Cup 6894 in place. Failure to do so may result in sickness or death. FITTING INSTRUCTIONS Must be followed each time respirator is worn.
  • Page 9 Negative Pressure User Seal Check with 6000 Series Cartridges 1. Place palms of hands to cover face of cartridge or open area of 3M™ Filter Retainer 501 and inhale gently. If you feel the facepiece collapse slightly and pull closer to your face with no leaks between the face and facepiece, a proper seal has been obtained (Fig. 12).
  • Page 10: Fit Testing

    NOTE: Fit testing is a U.S. Occupational Safety and Health Administration (OSHA), a Canadian CSA and a Brazilian BMOL requirement. Quantitative Fit Testing Quantitative Fit Testing (QNFT) can be conducted using a 3M™ Fit Test Adapter 601 and P100 filters such as the 3M™ Particulate Filters 2091 or 7093.
  • Page 11: Replacement Part Instructions

    Converting from the Standard Center Adapter 6864 to the DIN Port Adapter 6884 Any 3M™ Full Facepiece 6000 Series can be converted to the desired center adapter assembly by following the instructions in 3M™ Center Adapter Assembly Replacement and installing the Bayonet Caps 6880 with Inhalation Port Gaskets 6895 or the Full Face Plug 7800 with Breathing Tube Gasket 6876 as appropriate.
  • Page 12 3M™ Center Adapter Gasket 6896 Replacement The center adapter gasket replacement is designed to seal the interface between the center adapter and the lens of the Full Facepiece 6000 Series. 1. Remove nose cup assembly by pulling away from center adapter inside facepiece (Fig. 15).
  • Page 13 3M™ Frame Kit 6899 The frame kit 6899 includes a frame top, frame bottom, (2) Phillips head screws and (2) hex head nuts. The frame kit secures and seals the 3M™ Full Facepiece 6000 Series faceseal to the 3M™ Lens Assembly 6898.
  • Page 14 3M Personal Safety Division 3M CENTER, BUILDING 0235-02-W-70 ST. PAUL, MN 55144-1000 3M, Powerflow and Breathe Easy are trademarks of 3M or its affiliates, used under license in Canada. 3M PSD products are occupational use only. © 3M 2019 98-0060-0035-4_8...

Table of Contents

Save PDF