Download Print this page
3M 6000 Series Instruction Sheet
Hide thumbs Also See for 6000 Series:

Advertisement

Quick Links

Helping Y ou Wear it Right
Wearing your 3M
Full Facepiece
TM
Reusable Respirator 6000 Series
Always read and follow User Instructions.
1
2
3
4
5
Fully loosen all four head straps.
Pull hair back with one hand.
Bring facepiece up to face with
other hand.
While holding the facepiece in
place, pull the straps over your
head.
Tighten the two bottom straps.
Tighten the two top straps.
Make sure the back of the
harness is centered on the back
of the head.
Perform a User Seal Check
Before assigning any respirator to be worn in a contaminated area, a qualitative or quantitative
fit test must be performed per U.S. OSHA standard 29CFR 1910.134 or local requirements.
Positive Pressure User Seal Check
Place the palm of your hand over the opening in
the exhalation valve cover and exhale gently. If
facepiece bulges slightly and no air leaks are
detected between the face and the facepiece, a
proper seal has been obtained. If faceseal air
leakage is detected, reposition the respirator on
your face and/or readjust the tension of the
straps to eliminate leakage and recheck seal. If
you cannot achieve a proper seal, DO NOT
enter the contaminated area. See your
supervisor.
Negative Pressure User Seal Check
Using Particulate Filters
Place your thumbs onto the center portion of the
filters, restricting airflow through filters and inhale
gently. If you feel facepiece collapse slightly and
pull closer to your face with no leaks between the
face and the facepiece, a proper seal has been
obtained. If faceseal air leakage is detected,
reposition the respirator on your face and/or
readjust the tension of the straps to eliminate
leakage and recheck seal. If you cannot achieve a
proper seal, DO NOT enter the contaminated area.
See your supervisor.
Using Cartridges
Place palms of hands to cover face of cartridge or
open area of 3M™ Filter Retainer 501 and inhale
gently. If you feel facepiece collapse slightly and
pull closer to your face with no leaks between the
face and facepiece, a proper seal has been
obtained. If faceseal air leakage is detected,
reposition the respirator on your face and/or
readjust the tension of the straps to eliminate
leakage and recheck seal. If you cannot achieve a
proper seal, DO NOT enter the contaminated area.
See your supervisor.

Advertisement

loading

Summary of Contents for 3M 6000 Series

  • Page 1 Tighten the two top straps. Using Cartridges Place palms of hands to cover face of cartridge or open area of 3M™ Filter Retainer 501 and inhale gently. If you feel facepiece collapse slightly and pull closer to your face with no leaks between the face and facepiece, a proper seal has been obtained.
  • Page 2 A Storage Procedures for only method in place. During fit- respirator with any damaged or 3M Reusable Respirators testing, wipes may also be used deteriorated components must be between employees being tested. repaired or discarded.
  • Page 3 The 3M™ Center Adapter Assembly 6864 consists of a center adapter base, cover, exhalation valve and adapter gasket. It is secured to the center port of the lens on the 3M™ Full Facepiece 6000 Series with a bayonet style twist lock connection and sealed with a gasket.
  • Page 4 6894/37004* Nose Cup Assembly Replacement Instructions Important: Keep these User Instructions for reference * 37004 is a catalog number only. NIOSH approved as 3M 6894 Nose Cup Assembly. Fig. 1 Fig. 2 The 3M 6894 Nose Cup Assembly consists of a nose cup and inhalation valves. It is designed to...
  • Page 5: Spectacle Kit

    User Instructions (Important: Keep these User Instructions for reference) The 3M 6878/07141 Spectacle Kit consists of a frame assembly and a rail assembly. The frame assembly is the holder for the corrective lenses. The rail assembly supports the frame assembly in the facepiece and allows for up and down, in and out positioning of the frame assembly.
  • Page 6: Lens Cover

    6000 Series Full Facepiece Respirator. Remove release liner from adhesive at each side of 6885/07142 lens cover. Position lens cover over the 6000 Series Facepiece lens and adhere in place. Remove used lens cover by lifting tab away from facepiece.
  • Page 7: Lens Assembly

    6898/37006* Lens Assembly Replacement Instructions Important: Keep these User Instructions for reference *37006 is a catalog number only. NIOSH approved as 3M Lens Assembly 6898. See the 3M Full Facepiece 6000 User Instructions for approval label. 38-9018-9555-7 (Supersedes 38-9018-7177-2) Fig. 1 Fig.
  • Page 8 Fig. 3 3. Remove the (2) phillips screws from the lens/faceseal frame. Pull the frame top and bottom away from faceseal. 4. Remove faceseal from lens. 5. Place new lens and faceseal together aligning marks at top and bottom. Position top and bottom frame, again aligning marks top and bottom.

This manual is also suitable for: