Rear View - Mitsubishi Electric DX-ZD5UEZ Installation And Operation Manual

Hdd extension unit
Hide thumbs Also See for DX-ZD5UEZ:
Table of Contents

Advertisement

Major operations and their functions

Rear view

1
2
MAIN
AC IN
OFF
ON
100-240V
1. MAIN switch
This is the main power switch. When using this unit,
set this switch to ON.
2. AC power socket
Used to connect the power cord. Earth terminal is used
for safety. Use the 100 to 240 V plug with earth for the
power of this unit.
• When the power outlet does not have an earth
terminal, ask for your dealer of the earth work (pay
service). Never connect the earth terminal on the
power supply to a gas pipe, water pipe, conductor
rod, and so on.
• Please use the supplied AC power cord.
• Make sure to plug this unit into the outlet of the same
system which is being used for the recorder
connected. When this unit is plugged into the outlet
of other system, recording or copying after a power
failure will not be carried out correctly.
3. EXTERNAL CONTROL switch
Set this switch to ON (left side) to turn on and off the
power of this unit to link the recorder's switch. When
not linking the recorder, set this switch to OFF (right
side).
• When the EXTERNAL CONTROL switch is set to ON,
make sure to connect the CONT IN terminal of this
unit and DC 12V OUT terminal of the recorder, and
the GND terminal of this unit and GND terminal of the
recorder respectively. When the recorder is turned
on, this unit is turned on linking with the recorder.
• It is recommended to use this unit linking with the
recorder in order to give the internal hard disks a rest
or a proper countermeasure is taken when a problem
occurs on the recorder.
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
6
~
3
EXTERNAL
CONTROL
ON
4. I/O terminals
CONT IN terminal
Terminal for inputting the power on/off status of the
recorder. Connect this terminal with the DC 12V OUT
terminal of the recorder.
CONT OUT terminal
Terminal for outputting the power on/off status of the
recorder. When using multiple number of HDD exten-
sion unit and using the power on/off linkage function,
connect this terminal with the CONT IN terminal of the
unit to be connected.
GND terminals
They are the common GND terminals. When using the
power on/off linkage function, connect this terminal with
the GND terminal of the recorder.
TEMP ALM terminal
Terminal for informing the internal high temperature to
the external device.
FAN ALM terminal
Terminal for informing abnormality of the fan.
5. SERIAL BUS input port
Port for connecting with the recorder.
6. SERIAL BUS output ports
Ports for connecting with another DX-ZD5UE(Z) when
using multiple number of DX-ZD5UE(Z).
• It is impossible to supply 5V DC power from this port.
• Do not connect any devices other than DX-ZD5UE(Z)
to these output ports.
4
5
6
SERIAL BUS
OFF
IN
OUT