WHBV-101W-LH-NB and WHBV-101W-RH-NB
WARNING! The washbasin weighs approximately 35Kg. Always use safe lifting
procedures when lifting heavy loads. Make sure the washbasin is correctly
secured to the wall or correctly supported before working in the vicinity.
NOTE: Make sure you do not abrade or damage water tubes & waste pipe when
you insert them through the wall.

5.5 Water and Waste Connections

NOTE: The connection of the water supply and waste must be completed in
accordance with the plumbing code AS/NZS 3500
NOTE: Before you carry out the following steps, flush the water supply pipes to
remove any debris and trapped air.
NOTE: Fit a Y strainer in the water supply feed pipe before connection to the
washbasin, especially on older installations where loose particles from ageing
water pipes can cause a blockage.
NOTE: Fit a service isolating tap on the water supply feed. This allows for ease
of
maintenance when required. The isolating tap is not supplied with the
product and should be purchased separately.
NOTE: Use of any pipe sealing compound should be avoided to prevent
blockages & damage to the basin faucet.
1. Complete the connection of the water supply to the basin tap outlet.
2. Connect the waste pipe adapter to a deep seal waste trap.
NOTE: The trap must be fitted at a lower height than the basin waste pipe for
correct drainage. Fit an elbow connector to the waste pipe first before
dropping down to the trap inlet connection.