D1xB2LD2
LED Beacon
For use in Hazardous Locations
1) Warnings
 DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
 DO NOT OPEN WHEN ENERGISED
 POTENTIAL ELECTROSTATIC CHARGING
HAZARD - CLEAN ONLY WITH A DAMP
CLOTH
 DO NOT PAINT
 TO REDUCE THE RISK OF IGNITION OF
HAZARDOUS ATMOSPHERES, THE FIRST
CONDUIT RUN MUST HAVE A SEALING
FITTING CONNECTED WITHIN 18 INCHES
OF ENCLOSE. SUBSEQUENT CONDUIT
RUNS MUST HAVE A SEALING FITTING
CONNECTED AS CLOSE AS PRACTICAL TO
THE WALL OF THE ENCLOSURE, BUT IN
NO CASE MORE THAN THE SIZE OF THE
CONDUIT OR 50MM, WHICHEVER IS THE
LESSER.
 TO PREVENT IGNITION OF GROUP A, B, C
AND D ATMOSPHERES - SEE
INSTRUCTION FOR CHEMICAL
COMPATIBILITY
Avertissement:
 NE PAS OUVRIR UN PRESENCE
D'ATMOSPHERE EXPLOSIVE
 NE PAS OUVRIR ENERGIE
 DANGER POTENTIEL CHARGE
ÉLECTROSTATIQUE - NETTOYER
UNIQUEMENT AVEC UN CHIFFON HUMIDE
 NE PAS PEINTURER
 POUR RÉDUIRE LE RISQUE
D'INFLAMMATION DES ATMOSPHÈRES
DANGEREUSES, LE PREMIER CONDUIT DE
CONDUIT DOIVENT AVOIR UN RACCORD
D'ÉTANCHÉITÉ RACCORDÉ À MOINS DE 18
POUCES DE L'ENFERMEMENT. POUR
SUBSÉQUENT LES CONDUITES DE
CONDUIT LA DISTANCE ENTRE LA
SURFACE DE LA MASSE DE REMPLISSAGE
AU PLUS PRÈS DE L'ENVELOPPE DOIT
ÊTRE AUSSI PETITE QUE CE QUI EST
RÉALISABLE MAIS EN AUCUN CAS
E2S Warning Signals
Impress House, Mansell Road, Acton, London W3 7QH
Document No. D191-00-401-IS
Issue 3
28-11-22
D1xB2LD2
SUPÉRIEURE À LA PLUS PETITE DES
DIMENSIONS CORRESPONDANT À LA
TAILLE DU CONDUIT OU À 50 MM.
 POUR PRÉVENIR L'INFLAMMATION DES
ATMOSPHÈRES DES GROUPES A, B, C ET
D-VOIR L'INSTRUCTION POUR LA
COMPATIBILITÉ CHIMIQUE
2) Rating & Marking Information
2.1 NEC & CEC Class / Division Ratings for US /
Canada
The D1xB2LD2 LED beacons comply with the following
standards:
UL 1203 (Ed. 5) 2015
CSA C22.2 No. 30-M1986 (Ed. 1) 2003
CSA C22.2 No. 25 (Ed. 4) 2017
CSA C22.2 No. 205 (Ed. 3) 2017
The D1xB2LD2 LED Beacon is rated as follows:
Class I Div 1 Group ABCD T5 Ta -55°C to +80°C
Class I Div 1 Group ABCD T6 Ta -55°C to +75°C
Class II Div 1 Group EFG T5 Ta -55°C to +80°C
Class III Div 1 Ta -55°C to +80°C
Installation must be carried out in compliance with the
National Electric Code / Canadian Electric Code
www.e2s.com
Tel: +44 (0)208 743 8880
Sheet 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D1 B2LD2 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for E2S D1 B2LD2 Series

  • Page 1 SURFACE DE LA MASSE DE REMPLISSAGE AU PLUS PRÈS DE L’ENVELOPPE DOIT ÊTRE AUSSI PETITE QUE CE QUI EST RÉALISABLE MAIS EN AUCUN CAS E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
  • Page 2 UKCA Marking and 0518 Notified Body No. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D191-00-401-IS...
  • Page 3: Special Conditions Of Use

    MARKED # BEACON 3/4" NPT BOTTOM ENTRY FOR POLE MOUNTING BEACON Fig. 1 Fixing Location for Beacon E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D191-00-401-IS Issue 3 28-11-22...
  • Page 4: Cable Connections

    For use in explosive gas atmospheres, a minimum ingress protection rating of IP54 must be maintained. NPT plugs should be greased before insertion. Fig. 6 D1xB2LD2AC Terminals E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
  • Page 5: Line Monitoring

    4mm in size. External Earth Stud Internal Earth Terminal Fig. 9: Internal & External Earth Locations E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D191-00-401-IS Issue 3 28-11-22...
  • Page 6: Maintenance, Overhaul & Repair

    “Safe” failure rate (unrevealed) equipment. System type The Beacon lens cover is interchangeable, contact E2S Ltd for Hardware Fault Tolerance a replacement lens cover available in various colours. Diagnostic Coverage >...
  • Page 7 Page left Intentionally blank...
  • Page 9 Page left Intentionally blank...
  • Page 10: Eu Declaration Of Conformity

        Manufacturer:      European Safety Systems Ltd.        Impress House, Mansell Road, Acton        London, W3 7QH        United Kingdom    Authorised Representative:  E2S Warnsignaltechnik UG        Charlottenstrasse 45‐51        72764 Reutlingen        Germany      Equipment Type:   D1xB2X05, D1xB2X10, D1xB2X15, D1xB2X21, D1xB2LD2, D1xJ2    Directive 2014/34/EU: Equipment and Protective Systems for use in Potentially Explosive Atmospheres (ATEX)  Notified Body for EU type Examination (Module B): ...
  • Page 11 II 2G Ex d IIC T6…T3 Gb  II 2D Ex tb IIIC T95°C…T169°C Db   Standards applied:  EN 60079‐0:2018  EN 60079‐1:2014  EN 60079‐31:2014  IP6X Dust Protection to EN60079‐0 / EN60079‐31  Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)   Standards applied:  EN 61000‐6‐1:2007  EN 61000‐6‐2:2005  EN 61000‐6‐3:2007 / A1:2011 / AC: 2012  EN 61000‐6‐4:2007 / A1: 2011  Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)  The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic    equipment, including amendment by Directive 2015/863/EU. Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)  The product and all the components contained within it are free from substances of very high concern.  Other Standards and Regulations  EN 60529:1991 + A1:2000 + A2:2013. ‐ Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67    On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment  conforms with all technical and regulatory requirements of the above listed directives, regulations and standards.      This Declaration is issued under the sole responsibility of the manufacturer.       Martin Streetz  Document No.:  DC‐096_Issue_A  Quality Assurance Manager  Date and Place of Issue:  London, 24/02/2022      E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com  DC‐096_Issue_A ‐ Page 1 of 1 ‐ QAF_252_Issue_5...
  • Page 12 Page left Intentionally blank...