Ba Unit / Sci Cable - Epson EB-S01 Service Manual

Business/home projector
Hide thumbs Also See for EB-S01:
Table of Contents

Advertisement

EB-S01/W01/X14G/S11/X11/S02/S02H/X02/W02/S12/S12H/X12/W12/X14 EH-TW480

3.3.11.1 BA Unit / SCI Cable

Standard Operation Time
15 Min.
BA Unit is designated as the Safety Device. When removing/
replacing the BA Unit for repair, be sure to refer to "3.4 Safety
Check after Servicing (p.103)". According to the instructions in
it, handle the part and perform the procedure after servicing.
1.
Remove the Air Filter.
(p.59)
2.
Remove the Lamp.
(p.60)
3.
Remove the Upper Case (assembly).
4.
Remove the MA Board (assembly).
5.
Remove the Optical Engine.
(p.82)
6.
Remove the Lamp Fan.
(p.86)
7.
Remove the EX Duct (assembly).
8.
Remove the BA Power Supply (assembly).
9.
Open the BA Insulation Sheet.
10. Release the three hooks of the BA Power Supply (assembly) and remove the BA
Unit.
11. Disconnect the connector of the BA Cable from the BA Unit.
12. Release the SCI Cable from the groove (1) of BA Insulation Sheet.
13. Remove the BA Unit from the BA Insulation Sheet.
14. Remove the BA Lamp Cable from the BA Unit.
15. Remove the SCI Cable from the BA Unit.
16. Release the BA Cable from the groove (2), and remove the BA Insulation Sheet.
SEIKO EPSON
(p.62)
(p.74)
(p.87)
(p.89)
Disassembly and Assembly
BA Insulation
Sheet
BA Power Supply
(assembly)
93
BA Lamp Cable
BA Unit
Groove (1)
Groove (2)
Hook
Hook
Hook
Figure 3-32.
CONFIDENTIAL
SCI Cable
BA Cable
Revision C