EB-S01/W01/X14G/S11/X11/S02/S02H/X02/W02/S12/S12H/X12/W12/X14 EH-TW480

3.3.6.2 MA Board / RS Board (EB-S11/X11 only)

Standard Operation Time
12 Min.
MA Board is designated as the Safety Device.When removing/
replacing the MA Board for repair, be sure to refer to "3.4 Safety
Check after Servicing (p.103)". According to the instructions in
it, handle the part and perform the procedure after servicing.
1.
Remove the Air Filter.
(p.59)
2.
Remove the Lamp.
(p.60)
3.
Remove the Upper Case (assembly).
4.
Remove the MA Board (assembly).
5.
Remove the IF Case.
(p.78)
6.
Remove the seven screws.
7.
Release the hook of the IF Shade Case from MA Plate and remove the IF Shade
Case and the MA Plate.
8.
Remove the INT Fan Cushion from the MA Board.
9.
Remove the RS Board from the IF Shade Case.
(EB-S11/X11 only)
SEIKO EPSON
Disassembly and Assembly
(p.62)
(p.74)
MA Plate
Hooks
RS Board
RC Cable
79
CONFIDENTIAL
MA Board
INT Fan Cushion
IF Shade Case
C.C.SCREW,2.5X6,F/ZN-3C
C.B.P-TITE SCREW,3X8,F/ZN-3C
C.B.SCREW,3X6,F/NI
1/4-40X1/4,H.H.,F/NI,O SCREW
Figure 3-21.
Revision C

Hide quick links: