6. OPERATING INSTRUCTIONS

ATTENTION: The temperature during operation must be between -10°C and +50°C.
ANDERSON PLUGS USE (DC operation)
The DC12V Anderson plugs on LithPowerUnit provide a convenient option to connect DC12V appli-
ances and accessories such as DC fridge, DC TV, electric pumps, light kits etc.
The LithiumPowerUnit 80 is equipped with 5 * Anderson plugs:
1 * 175Amp plug
(the 175 A Anderson plug can be connected to an external inverter, max. 1800 W).
3 * 50Amp plug (can be used as input and output plug).
1 * 15Amp solar input.
The LithiumPowerUnit 120 is equipped with 5 * Anderson plugs:
1 * 175Amp plug
(the 175 A Anderson plug can be connected to an external inverter, max. 1800 W).
2 * 50Amp plug (can be used as input and output plug).
1 * Anderson in-vehicle charging input 50Amp.
1 * 30Amp solar input.
NOTE: Before doing the charge or discharge, please turn on the Battery Main Switch firstly. The
charging current or discharging current of 50 Amp Anderson plug must be less than 50A, other-
wise, the circuit breaker will be triggered and cut off the power.
CAUTION! The circuit breaker of 50Amp Anderson plug resets automatically, please check the
connections and make sure the electrical fault in the circuit is fixed. The circuit breaker will be trig-
gered again, if an electrical fault still exists. Please avoid short circuit of any Anderson plug!
A 40A inline fuse cable is provided for the MPPT solar charge controller which protects the device.
USB Port & Cigarette Lighter Socket
There are 2 * 2.1Amp USB ports and 2 * cigarette lighter sockets (against customized require-
ment) on LithPowerUnit to charge personal electronics.
NOTE: Before charging your personal electronics, please turn on the Battery Main Switch firstly.
The charging current must be less than 10A of each plug, otherwise, the circuit breaker will be trig-
gered and cut off the power. If the internal 30A fuse is broken due over-current it must be
replaced.
CAUTION! Before replacing the circuit breaker, please check the connections and make sure the
electrical fault in the circuit is fixed. The circuit breaker will be triggered again, if an electrical fault
still exists.