Programming The Water Softener - Miele Diamante Plus G2183SCVI Operating Instructions Manual

Miele diamante plus g2183scvi: user guide
Table of Contents

Advertisement

Before using for the first time
Programming the water
softener
To exit the programming mode at
any time, turn the dishwasher off
with the "O" button.
^ Turn the dishwasher off with "o".
^ Press and hold the "Program" and "g"
buttons simultaneously. Hold the
program button until the lower right
program indicator lights.
If it does not come on, start over.
^ Press the "Program" button twice.
The "Intake/Drain" indicator
The "Intake/Drain" indicators flashes
twice in the display.
The "SaniWash" indicator flashes once
in intervals (factory default).
^ Press the "Program" button for at
least one second, until the
"Intake/Drain" indicator lights up.
12
The amount set can be recognized by
the flashing rhythm of the "SaniWash"
indicator (see table):
°d
gr/gal
1 - 4
1 - 4
5 - 7
5 - 7
8 - 11
8 - 11
12 - 15
13 - 16
16 - 20
17 - 21
21 - 25
22 - 26
26 - 30
27 - 31
31 - 36
32 - 38
37 - 45
39 - 47
46 - 70
48 - 73
^ Select the desired setting with the
"Program" button. Every touch of the
button increases the level.
The programmed dosage is saved.
^ Turn the dishwasher off "V".
Checking the programmed water
hardness level
^ Turn the dishwasher off "V".
^ Press the "Program" button, at the
same time turn the dishwasher on "g".
Hold the "Program" button in until the
indicator lights up.
^ Press the "Program" button twice.
The amount set can be recognized by
the flashing rhythm of the "SaniWash"
indicator (see table).
^ Turn the dishwasher off "V".
Flashing rhythm
once
twice
3 times
4 times
5 times
6 times
7 times
8 times
9 times
1 long flash

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: