Information About the Sprayer
Roller pumps are positive displacement pumps, which means
that the entire solution being pumped must go somewhere or
the pump will break. In this roller pumping system, solution is
drawn from the tank and forced to a planned source, such as
boom nozzles or handgun. The pressure is controlled by a
pressure relief valve, which is a spring-loaded device that
controls the amount of fluid bypassed (recirculated) to the
tank. The gray adjusting cap is to be tightened to
increase pressure and loosened to decrease pressure.
The 'directo-valve' is the on/off control which allows the
operator to manually control the solution going to the boom.
General Information
Thank you for purchasing this product. The purpose of this
manual is to assist you in operating and maintaining your
3-Point sprayer
BEFORE RETURNING THIS PRODUCT
FOR ANY REASON, PLEASE CALL
1-800-831-0027
MONDAY-FRIDAY, 8:00 AM TO 5:00 PM CST
If you should have a question or experience a problem with
your Fimco Industries Product: Visit our website @
www.fimcoindustries.com or call the Toll free number above. Our
technical support representatives will be happy to help you.
In most cases a customer service rep. can resolve
the problem over the phone.
To obtain prompt, efficient service, always remember to give the
following information....
• Correct Part Description and/or part number
• Model number and Serial Number
Part descriptions and numbers can be obtained from the
illustrated parts list section(s) of this manual.
Retain a copy of your receipt for your unit, as it will be required
to validate any warranty service.
Warranted against manufacturer or workmanship defects from
date of purchase with copy of receipt:
Homeowner Usage: One Year.
Commercial Usage: 90 Days.
OWNER'S MANUAL
Caution: When fully filled with water, this sprayer will
weigh approx. 700 lbs.. Consult the owner's manual for
your vehicle to verify that you are within it's load carry-
ing capacity.
Assembly Instructions
Most of the sprayer has been assembled at the factory.
Center the boom tube on the boom mounts and secure in
place with the (2) round U-bolts and whiz nuts provided.
Make sure the U-bolts are positioned within the grooves of
the grommets on the boom tube. Refer to page 2 to attach
the end nozzles to the boom.
NOTE: The purpose of these grommets is to prevent met-
al-to-metal contact between the U-bolts, boom tube and
boom mounting brackets.
The grommets will 'compress' as you tighten the whiz lock-
nuts onto the U-bolts. Tighten just so that the boom tube will
NOT rotate within the grommets. Alternate the tightening of
the locknuts to provide even pressure on the grommet.
**DO NOT OVER TIGHTEN the whiz locknuts, as this may
cause the boom tube to flatten slightly!
Attach the boom feeder hose to the boom after routing it
through the underside of the carrier frame as needed. Secure
in place with a hose clamp provided.
Poly hose fittings (5010209) are included to be joined to the
pump. A torque chain, 'S'-Hook and hardware are also includ-
ed for the pump. The pump IS NOT included with this unit. It
is intended for a pump to be mounted directly to the tractor
PTO.
www.fimcoindustries.com
1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD 57049
Toll Free Phone: 800-831-0027 : Toll Free Fax: 800-494-0440
[5004598
Category I
(11/20)]
Page 1

Advertisement

loading

Summary of Contents for Fimco LG-60-3PT-BL

  • Page 1 Warranted against manufacturer or workmanship defects from date of purchase with copy of receipt: www.fimcoindustries.com 1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD 57049 Homeowner Usage: One Year. Toll Free Phone: 800-831-0027 : Toll Free Fax: 800-494-0440 Commercial Usage: 90 Days.
  • Page 2 End Nozzle Assembly Procedure For Boomless “Wet” Boom Your boom will come with the (2) end nozzle assemblies NOT affixed to your boom tube. Follow the instructions below to attach these properly to the boom tube, as shown. Assembled End Nozzle 1.
  • Page 3: Operation & Calibration

    IMPORTANT: Remove tank lid and be sure the tank is Four things must be considered before spraying with the boom.  clean and free of any foreign material. Rinse tank out How much chemical must be mixed in the tank. ...
  • Page 4 Drain and then refill half full, add the recommended amount of a good quality tank cleaner, such as FIMCO Tank Neutralizer and Cleaner. (If no tank cleaner is available, you may substitute dish soap for this step).
  • Page 5  1/2” NPT (F) Spray Line Connection  3/4” NPT (F) Continuous By-Pass Connection  Valves may be connected w/close nipples for multiple section spray control Ref. # Fimco # Mfg. Part # Description Qty. 5002476 CP36303-PP Poly Body (AA6B) ♦...
  • Page 6: Exploded View Parts List

    Exploded View/Parts List: LG-60-3PT-BL (5301340) Refer to Parts List Below for Part Numbers See Next Page See Valve Detail Next Page Pump NOT Included See Strainer Detail Next Page Page 6...
  • Page 7 Strainer Sub-Assembly #5274745 * * Only Available in Valve Complete Assembly Sub-Assembly Refer to Parts List 5277757 Previous Page for Part Numbers Boomless “Wet” Boom Assembly (5275260) Exploded View/Parts List End Nozzle Center Nozzle Assembly Assembly 5275122 5275123 Page 7...
  • Page 8: Warranty

    WHAT REMEDIES ARE AVAILABLE UNDER THIS LIMITED WARRANTY. If the conditions set forth above are fulfilled and the Equipment or any part thereof is found to be defective, Fimco, Ind. shall, at its own cost, and at its option, either repair or replace the defective Equipment or part.

This manual is also suitable for:

5301340