Installing The High-Pressure Stage; Fig. 16: Gaskets In The Slots Of The Bearing Casing - ABB Turbo Systems Switzerland Power2 550-M44 Operation Manual

High-pressure stage
Table of Contents

Advertisement

Operation Manual / Power2 550-M / High-pressure stage
3 Removal and installation / 3.3 Installing the high-pressure stage
3.3

Installing the high-pressure stage

3.3.1
Inserting gaskets
CAUTION
Inserting the gaskets
Gaskets that are forgotten, damaged or improperly inserted will lead to oil
leaks.
Always use new gaskets and insert them carefully into the slot.
u
Fig. 16: Gaskets in the slots of the bearing casing
42001
Bearing casing
42198
O-ring
42199
O-ring
01
Oil supply
02
Oil drains
The oil is supplied (01) and drained (02) through the bracket.
Insert the O-rings (42198 and 42199) into the slots of the bearing casing.
u
© Copyright 2022 ABB. All rights reserved.
HZTL4058_EN
Rev.F
March 2022