BEFORE RETURNING THIS PRODUCT
FOR ANY REASON, PLEASE CALL
1-800-831-0027
MONDAY-FRIDAY, 8:00 AM TO 5:00 PM CST
If you should have a question or experience a problem with
your Fimco Industries Product: Visit our website @
www.fimcoindustries.com or call the Toll free number above. Our
technical support representatives will be happy to help you.
In most cases a customer service rep. can resolve
the problem over the phone.
To obtain prompt, efficient service, always remember to give the
following information....
• Correct Part Description and/or part number
• Model number and Serial Number
Part descriptions and numbers can be obtained from the
illustrated parts list section(s) of this manual.
General Information
Thank you for purchasing this product. The purpose of this
manual is to assist you in operating and maintaining your
skid sprayer.
Retain a copy of your receipt for your unit, as it will be required
to validate any warranty service.
Warranted against manufacturer or workmanship defects from
date of purchase with copy of receipt:
Homeowner Usage: One Year
Commercial Usage: 90 Days.
OWNER'S MANUAL
Model: LSS-240 (5301259)
Technical Specifications
200 Gallon Polyethylene Tank
Maximum Flow = 10.6 GPM
Maximum Pressure = 580 PSI
Maximum Temperature = 140°F
High Pressure Spray Gun w/1/2" x 300' of Hose
Banjo Garden Hose Spray Nozzle
Delta Jet Agitator
Caution: When fully filled with water, this sprayer will
weigh approx. 2,070 lbs..
Consult the owner's manual for your vehicle to verify
that you are within it's load carrying capacity.
Before Operating the Sprayer
1.
Add proper oil to the engine crankcase and gasoline to
the gas tank. Always check the oil in the gear box. Refer
to engine manual for correct oil type. Add SAE 30 to the
sight level in the diaphragm pump. Fill the gear case with
90W gear lube until the gear lube runs out the side plug
hole.
2.
Add plain water to the tank and check the system for
leaks. Open the suction line valve. Open the lever valves
by the pressure regulator that are connected to the hand-
gun line and jet agitator line.
3.
The pumping system includes an agitator, which will help
keep the solution in suspension. Pressure to the agitator
should never exceed 100 PSI. When spraying at pres-
sures over 100 PSI, use the valve (in the agitator line) to
throttle the pressure to the agitator by closing the valve.
The valve may be opened slowly until the gauge reaches
100 PSI.
Do not exceed recommended pressure on pump or
sprayer, as it may cause hoses to burst and will shorten
pump life.
***WARNING***
This product when used can be dangerous and can cause
bodily harm, only if not properly used or guarded.
* STAY AWAY FROM EQUIPMENT
WHEN IT IS IN OPERATION *
Read information and the full instructions furnished with the
before installing and operating.
www.fimcoindustries.com
1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD 57049
Toll Free Phone: 800-831-0027 : Toll Free Fax: 800-494-0440
[5004575
product
(12/20)]
Page 1

Advertisement

loading

Summary of Contents for Fimco LSS-240

  • Page 1 Warranted against manufacturer or workmanship defects from www.fimcoindustries.com date of purchase with copy of receipt: 1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD 57049 Homeowner Usage: One Year Toll Free Phone: 800-831-0027 : Toll Free Fax: 800-494-0440 [5004575 (12/20)] Commercial Usage: 90 Days.
  • Page 2: Important Reminder

    Drain and then refill half full with plain water, add the recommended amount of good quality tank cleaner such as FIMCO Sprayer Tank Neutralizer and Cleaner. (If no tank cleaner is available, you may substitute dish soap for this step, about 1-2 oz.
  • Page 3 Exploded View: LSS-240 (5301259) Refer to Parts List next page for Part Numbers See Reel/ Agitator Plumbing Detail Next Page See Engine/Pump Detail Next Page See Strainer Detail Next Page Page 3...
  • Page 4 Parts List: LSS-240 (5301259) Engine/Pump Detail Strainer Detail * * Available ONLY in Complete assembly. Reel/Agitator Plumbing Detail Page 4...
  • Page 5: Troubleshooting Guide

    Troubleshooting Guide Symptom Probable Cause(s) Corrective Action One or more valves are seating improperly. Examine the valve seatings and clean them. The pump does not draw water Suction line is plugged or collapsed. Examine suction line. Clean Strainer. Clogged strainer. The pump is sucking in air through the Examine the suction hose and make sure it is Pressure gauge fluctuates excessively...