4. System examples
4.1. System with a GX device, on/off switch and pre-alarm circuit
1
On
4
Off
#
Description
1
AC source, grid or generator
2
Circuit breaker
3
MultiPlus-II Inverter/charger
4
Remote on/off switch
5
VE.Bus BMS V2
6
Cerbo GX
7
AC-DC power supply, providing backup power to the Cerbo GX should the battery be too far discharged
8
Pre-alarm warning circuit, giving an advanced warning in case of an imminent system shutdown due to a too far
discharged battery
9
Lithium Battery Smart or battery consisting of multiple batteries creating a 12V, 24V or 48V battery bank
Page 13
VE.Bus BMS V2
2
6
5
Pre-alarm
8
warning
circuit
9
3
AC/DC
7
power
supply
System examples