2) Loosen screws B and open frame A.
3) Unlock shutter C and turn down the gear-tray,
disconnect plug connector D and remove the
gear-tray.
D
B
A
C
4) Cut the connecting cable X corresponding to
the height of the pole and insert it via the bra-
cket E through the cable gland F inside the
luminaire. Connect the neutral conductor (N),
phase (L1) and the
earthing to the corres-
ponding marked contacts of the terminal
clamp D.
Class II: No protection earth is required. The
power cable has to be double insulated accor-
ding to class II.
5) Firmly tighten cable gland F, fasten the conduit
and install the bracket E to the luminaire.
6) Put in gear-tray, close plug connection D an
close the gear-tray. Make sure that the gear-
tray is firmly shut.
G
E
7) Close frame A and firmly tighten screws B.
8) Feed cable through top of column, while setting
luminaire in position. Secure luminaire by evenly
tightening the six hexagon socket screws G.