TECHNICAL DATA
TYPE
Thermal output
Net heat value
Gas
(Family 2)
Pressure
Electrical supply
Motor
Capacitor
Ignition transformer
Absorbed electrical power
BURNER DESCRIPTION
According to Directives: Electromagnetic Compatibility 89/336/EEC - 2004/108/EC, Low Voltage 73/23/
EEC - 2006/95/EC and Machine 2006/42/EC.
The burner meets protection level of IP X0D (IP 40), EN 60529.
Gas train according to EN 676.
1 – Air damper
2 – Screws for fixing the air damper
3 – Grommet
4 – Screw for fixing the cover
5 – Air pressure switch
6 – 6 Pole socket
7 – Lock-out lamp and reset button
8 – Control box
9 – Flange
10 – Motor
11 – 7 Pole socket
NOTES
– The grommet (3) supplied with the burner, must be fitted to the same side of the gas train.
– After having installed the burner verify the access to the fixing screws of the cover.
If necessary replace them with the fixing screws (4) fig. 1 supplied as equipment.
564M
23 – 58 kW
–
3
8 – 12 kWh/m
– 7,000 – 10,340 kcal/m
min. 10 mbar – max. 40 mbar
single phase, 230 V ± 10%
230 V / 0.65 A
2 F
primary 230 V – secondary 15 kV
0.15 kW
7
8
5
4
3
1
20,000 – 50,000 kcal/h
~
50Hz
Fig. 1
6
10
11
3
9
1
2
D7572
20025473