Download Print this page

NEC N8104-125A Startup Manual page 4

Advertisement

Precautions for Installation, Relocation, Storage and Connection
Do not use any unauthorized interface cable.
Use only interface cables authorized by NEC and locate a proper device and connector
before connecting a cable. Using an authorized cable or connecting a cable to an improper
destination may cause a short circuit, resulting in a fire.
Also, observe the following notes on using and connecting an interface cable.
Do not use any damaged cable connector.
Do not step on the cable.
Do not put any object on the cable.
Do not use the card with the loose interface cable connection.
Do not use any damaged cable.
Do not use the equipment in the place where corrosive gases
exist.
Make sure not to locate or use the equipment in the place where corrosive gases (sulfur
dioxide, hydrogen sulfide, nitrogen dioxide, chlorine, ammonia, ozone, etc) exist.
Also, do not set it in the environment where the air (or dust) includes components
accelerating corrosion (ex. sulfur, sodium chloride) or conductive metals.
There is a risk of a fire due to corrosion and shorts of an internal printed board.
Contact your service representative for the place appropriate to the equipment.
Precautions for Handling of Internal Devices
Do not disassemble, repair, or modify the product yourself
Do not disassemble, repair, or modify this product. Doing so may cause an electrical shock
or a fire. Do not put the product close to fire, or immerse it in water. Doing so may cause an
explosion. If the product does not function normally, contact your service representative.
Unplug all power cords
Turn the power off and unplug the power before removing the computer's cover. Failure
to do so could endanger you and may damage the adapter or computer
Precautions for Handling
Avoid installation in extreme temperature conditions.
Immediately after the server is powered off, its internal components such as heat sink are
very hot. Leave the server until its internal components fully cool down before
installing/removing any component.
Ground yourself to dissipate any static charge before handling
the adapter.
To prevent any damage on components due to static electricity, make sure to discharge
static electricity from yourself before you touch N8104-125Aadapter.
Don't touch uncoated metal parts on adapter.
Never touch N8104-125A adapter's LAN port, terminals of components or uncoated metal
parts on adapter. Otherwise, taint, erosion or others may cause loose connection. Do not
touch this product with wet or dirty hands.
Excessive force could break the connector.
On installing this adapter, do not insert it by force. Otherwise, N8104-125A adapter and
the server may be damaged.
本書は再生紙を利用しています This guide is made from recycled paper.
Don't touch the tip of bracket to other parts of server
When you insert N8104-125A adapter into expansion slot, be careful not to touch the tip of
bracket to other parts of server (such as other components or board). Otherwise, they
may be damaged.
Firmly connect the network cable
When connecting the cable, insert the cable connector until you hear a click sound.
Precaution on disposing or transferring
- Follow the ordinances by your local government when you are disposing the product.
Contact the local government for more information.
- If you are transferring this product to other people, be sure to transfer all items that
come with the product including this guide along with the product.
Description
Bracket
Bracket
LAN port
PCI-Express Connector
LAN Port
A Connector to access to the network. For the types of connectable cables and
how to connect, see "Network Cables"
PCI-Express Connector
Attach PCI–Express connector to PCI-Express expansion slot in the server.
This adapter supports more than x4 lane (or higher), and is compliant with
PCI-Express 1.0a (or newer) specifications.
Bracket
low-
bracket is attached by default. If you have a full-height computer
profile
cabinet, replace the bracket to full-height bracket.
Lamp
lamp
Status
Meaning
Green On
The adapter is connected to a valid link partner.
Green
ACT/LNK
Data activity
flashing
Off
No link.
Off
10Mbps
SPEED
Green
100Mbps
Orange
1000Mbps
- 4 -
Network Cable
Connector
RJ45
Twisted Pair Cable( UTP / STP ) Must be 4pair wiring
Type
Make sure you use cable that complies with the TIA-568 wiring specification.
10BASE-T: Cat.3 or better,
Cable Category
100BASETX : Cat.5 or better
1000BASE-T Cat.5e or better
Length
100 m (max.)
LAN Port
LNK/ACT
The width of the root portion of a plug should
Port A
SPEED
Port B
Port C
Port D
Hardware Installation / Uninstallation
Refer to the User's Guide of the server.
Bracket Replacement
1
Remove screw.
Screw
3
Slide the bracket down.
Driver software Installation
With the "EXPRESSBUILDER" attached to the server, install the driver software of the adapter to the
server. Refer to the User's Guide of the server about the installation of driver software.
N8104-125A 1000BASE-T Adapter Startup Guide
NEC Corporation
Refer to the left figure which does
less than12mm
not get used to use for the cable with
boots (with a connector cover).
11.58~11.79mm
based on ISO standard.
* The cable with boots causes of
poor contact and a connector
use the cable within 12mm.
breakage.
cable boots
2
Slide the bracket upward.
4
Fasten the screw.
Screw
1st.Edition
April 2010
7-1 Shiba 5-Chome, Minato-Ku
Tokyo 108-8001, Japan
*856-127021-125- AO*

Advertisement

loading