405A/B
Air-compressing Nebulizer
User's manual
Please read the user's manual closely!

Advertisement

loading
Need help?

Need help?

Do you have a question about the 405A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Yuwell 405A

  • Page 1 405A/B Air-compressing Nebulizer JIANGSU YUYUE MEDICAL EQUIPMENT & SUPPLY CO., LTD. User's manual Sales Center Address: Huanyuan East Road No.1, Xuzhuang Software Park, Nanjing, Jiangsu Province, P.R. China, 210000 Manufacturing Address: YunYang Industrial Park, DanYang, Jiangsu Province, P.R. China, 212300 Please read the user's manual closely! http://www.yuwell.com...
  • Page 2 405A about 260g (unit only) 405B about 240g(unit only) 8. Size: 405A Approx. 13cm (l) × 6.5cm (w) ×6.8cm (h) 405B Approx. 14.5cm (l) ×8cm (w) ×5.6cm (h) 9. Taboo: None 10. Electrical safety requirements: Class II equipment, Type B...
  • Page 3 11. Working system: intermittent operation – working for 20 top of the septum can turn into very fine aerosol before ejecting minutes with an interval of 40 minutes to the outside. 12. Normal working conditions: Baffle Environmental temperature: 10℃~40℃ R e l a t i v e h u m i d i t y : 30%~75% Aerosol Aerosol...
  • Page 4 Figure 4: Schematic diagram of components (405B) Air Outlet Medication Holder Mouthpiece Baffle Power Switch Main unit Power plug Air tube Figure 3: Schematic diagram of components (405A) Medication cup Mask Air tube Figure 5: Schematic diagram of the nebulizer kit and accessories...
  • Page 5 1. Open the cap. 2. Add the correct amount of 4. Turn the power switch to the off ("○") position. prescribed medication to the medication cup. 405A 405B 5. Plug the AC adapter with 6. Plug the adapter into a the main unit.
  • Page 6 ※ Use on holder Please use the holder when temporarily placing medication cup. 405A 405B 2. As the main unit starts, connect the air tube to the connector of the main unit and the medication cup respectively.
  • Page 7 Make sure the air tube is firmly connected to the main unit and the medication cup. 3. Hold the nebulizer kit for treatment. 405A 405B 5. Disconnect the nebulizer kit from the air tube. 6. Check the air tube. No condensation or moisture should remain in the air tube.
  • Page 8 to ensure hygienic cleaning. Add appropriate amount of vinegar according to instructions on disinfectant, sufficiently wash the in the water, and then dry naturally in a clean place. units with clean water, and take care to avoid residual disinfectant 2) Main unit and air tube for disinfectant inhalation may cause worsening of symptoms.
  • Page 9 Please select the disinfection method listed in the following table: Ingredient: alcohol Sterilization Main disinfectant: Part name Material by boiling disinfection with ethanol 405A 405B ○ ○ Mouthpiece 2. Replace the filter. Remove the old filter sheet with a toothpick or other tools and ○ ×...
  • Page 10 Caution: IX. Common Failure Analysis and Troubleshooting Do not use or store when the air tube is bending. Symptom Analysis Solution Do not let the main unit, nebulizer kit, AC adapter drop or subjected to strong shocks. The device is The air filter cover Attach the air filter cover Do not apply force to the air tube and the nebulizer kit to deform.
  • Page 11 user or others or damages. Warnings and notes are in the X. Notes following: 1. General Safety Precautions: Legend Content 1) Check the main unit and accessories, confirm the existence of It indicates that misuse may lead to personal injury or any problems and pay particular caution to the following: Caution property damage.
  • Page 12 Yuwell. III. Sale and others Do not use damaged components, mouthpiece, mask and air tube. I. Sale Do not cover the main unit and AC adapter with a blanket or 1. If there is any quality problem caused by non-human factors towel, or any other type of cover during use.
  • Page 13 Inform: II. List of accessories 1. For machine damages and failures caused by improper use or Attachment Quantity not following the instructions, the company shares no Main unit responsibility. Nebulizr kit 2. When the conditions of temperature, voltage, and product Mouthpiece characteristics are not in line with defined indicators, the main Air tube...