Summary of Contents for Garland EdgeLens INT10G8SR56

  • Page 1 User Guide INT10G8SR56 / INT10G8LR56 12/2022 Release Version: 4.22.1 Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 2 The Garland Technology trademarks, service marks ("Marks") and other Garland Technology trademarks are the property of Garland Technology, LLC. PacketMAX Series products of marks are trademarks or registered trademarks of Garland Technology, LLC. You are not permitted to use these Marks without the prior written consent of Garland Technology.
  • Page 3: Table Of Contents

    IPv6 Enable IPv6 Disable Add SSL Certificate Disable Using Uploaded SSL Certificate Date & Time Timezone Manually Set Date & Time NTP No Authentication (Symmetric) Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 4 Decapsulate VXLAN Packets (VXLAN RX Only) Encapsulate l2GRE Packets (GRE TX Only) Decapsulate l2GRE Packets (GRE RX Only) Filter Template Load Balancing Group Load Balancing Policy Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 5 Disable Config Map Enable Config Map 5. Port Info Port Configuration Port Description Set Speed Mode Port Statistics VLAN Tag VLAN Strip Port Statistics Refresh Clear Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 6: Dashboard

    (GREEN). However, on the faceplate, the Ethernet Interface has LEDs to indicate link and activity while there are no Serial Interface LEDs. Dashboard Panel Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 7: Led Indications

    Port 33 Left Up Arrow Link LED Port 34 Left Down Arrow Link LED Port 35 Left Up Arrow Link LED Port 36 Left Down Arrow Link LED Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 8: Led Indications

    Tap 4 Bypass LED Port 15 Left Up Arrow Tap 4 Inline Appliance Link LED Port 16 Left Down Arrow Tap 4 Inline Appliance Link LED Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 9: Led Indications

    Tap 2 Secondary Inline Appliance Link LED L/A5 Tap 3 Network Port 5 Link/Activity LED L/A6 Tap 3 Network Port 6 Link/Activity LED Tap 3 Bypass LED Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 10: Led Indications

    Tap 3 Bypass LED Port 13 Left Up Arrow Tap 3 Primary Inline Appliance Link LED Port 14 Left Down Arrow Tap 3 Primary Inline Appliance Link LED Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 11: Led Indications

    Tap 1 Network Port 7 Link/Activity LED L/A8 Tap 1 Network Port 8 Link/Activity LED Tap 1 Bypass LED Port 9-15 Left Up Arrow Entity A Inline Appliance Link LED Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 12: System

    System Info SNMP General Export Configuration Admin Import Configuration Network Settings Software Upgrade Date & Time Reboot Syslog 1. Select System on the Dashboard Menu bar. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 13: System Info

    6. Select Cancel to return to the General System Settings panel. Admin The following configuration options may be displayed, modified, enabled or disabled. Users Groups Authentication Local Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 14: Groups

    2. Enter the Group Name. 3. Select the desired privileges. 4. Select Save to save updates. The new group will be displayed on the Admin Settings panel. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 15: Authentication

    This option may be used to verify the authentication of a TACACS user, password and authorization group. The TACACS Test option will be active only if TACACS authentication has previously been enabled. 1. Select TACACS Test. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 16: Tacacs Ping Test

    1. Select TACACS Test. The TACACS Test panel will appear. 2. Select Secondary. 3. Enter the Username. 4. Enter the Password. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 17: Tacacs Ping Test

    1. Select Network Settings. The Network Settings panel will be displayed with the current configuration IPv4 / Disable 1. Deselect Enable IPv4. 2. Select Save. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 18: Ipv6 Disable

    2. Select Choose File for Select Certificate. 3. Select the desired cert.pem file. 4. Select Open. 5. Select the Choose File for Select Key File. 6. Select the desired key.pem file. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 19: Disable Using Uploaded Ssl Certificate

    2. Select the desired Timezone using the pull down panel. 3. Select Save. 4. Select Cancel to return to the Date & Time Settings panel. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 20: Manually Set Date & Time

    If IPv6 is desired, then an IPv6 management interface must be assigned. The system allows for an IPv4 and IPv6 management interface to be assigned simultaneously. 1. Select Edit Settings. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 21: Syslog

    9. Select Cancel to return the Syslog Configuration panel. Syslog Test 1. Select Syslog Test. The GUI message will be displayed,”Syslog Test Successful!”. 2. Verify the Syslog Test Message on the Syslog server. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 22: Snmp

    14. Select Cancel to return the SNMP Configuration panel. SNMP Test 1. Select SNMP Test. The GUI message will be displayed,”Test Successful!”. 2. Verify the SNMP Test Message on the MIB Browser. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 23: Export Configuration

    This option allows the unit to be rebooted. The traffic will be affected for up to 1 minute. 1. Select Reboot. The Reboot Device panel will be displayed. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 24: Bypass Taps

    Taps panel. Default Tap Mode ATLB2 Chained Tap Mode Primary-Secondary Tap Mode Load Balance Tap Mode 1. Select Bypass Taps on the Dashboard Menu bar. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 25: Default Tap Mode

    Port 11 (Inline Appliance) Port 13 (Inline Appliance) Port 15 (Inline Appliance) Port 10 (Inline Appliance) Port 12 (Inline Appliance) Port 14 (Inline Appliance) Port 16 (Inline Appliance) Figure 1 Default Tap Mode Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 26: Bypass Tap Name

    4. Select Save to save updates. 5. Select Cancel to return the Bypass Taps panel. Taps Settings The following configuration options may be displayed, modified, enabled or disabled. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 27 If selected, the tap will switch the traffic between the network ports with no regard for the inline appliance port(s), link or heartbeats. Typically used during maintenance activities. Figure 4 Default Tap Mode (Force Bypass) Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 28 If enabled and the inline appliance port(s) fail, loss of link or heartbeats. The TX will be disabled on both of the network ports. The RX for both network ports remain on. Figure 7 Default Tap Mode (Reverse Bypass) Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 29: Monitor Ports

    Additional monitor ports may be added using the same procedure. 2. Select Save to save updates. 3. Select Cancel to return the Bypass Taps panel. Figure 8 Default Tap Mode (Monitor Port) Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 30: Primary-Secondary Tap Mode

    Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 31: Bypass Tap Name

    No. Of Lost HB Packets Heartbeats per Second 1. Select Settings on the Bypass Taps panel. The Configure Heartbeat Settings panel will be displayed with the current configuration. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 32: Configure Primary-Secondary Tap Mode

    1. Edit the Tap Settings, by placing the cursor on any tap and double-press the left mouse button. The Tap panel will be displayed. 2. Select Edit Tap Settings. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 33 Figure 10 Primary-Secondary Tap Mode (Primary Inline) Figure 11 Primary-Secondary Tap Mode (Secondary Inline) Figure 12 Primary-Secondary Tap Mode (Bypass) Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 34 The TX will be disabled on both of the network ports. The RX for both network ports remain on. Figure 15 Primary-Secondary Tap Mode (Reverse Bypass) Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 35: Switch To Primary

    Additional monitor ports may be added using the same procedure. 2. Select Save to save updates. 3. Select Cancel to return the Bypass Taps panel. Figure 16 Primary-Secondary Tap Mode (Monitor Port) Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 36: Load Balance Tap Mode

    The network traffic is load balanced to the inline appliance ports. However, heartbeat packets are transmitted bidirectionally from inline appliance ports on the tap through the IPSs or tools to monitor the health of the devices. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 37: Bypass Tap Name

    The following configuration options may be displayed or modified. No. Of Lost HB Packets Heartbeats per Second 1. Select Settings on the Bypass Taps panel. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 38: Configure Load Balance Tap Mode

    Bypass Threshold 1. Edit the Tap Settings, by placing the cursor on any tap and double-press the left mouse button. The Tap panel will be displayed. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 39 If selected, the tap will switch the traffic between the network ports with no regard for the inline appliance ports, link or heartbeats. Typically used during Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 40 1-4. The TX will be disabled on both of the network ports. The RX for both network ports remain on. Figure 22 Load Balance Tap Mode (Reverse Bypass, Bypass Threshold=2) Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 41: Atlb2 Chained Tap Mode

    Heartbeat packets are transmitted bidirectionally from the entity inline appliance ports on the tap through the IPSs or tools to monitor the health of the devices. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 42: Configure Atlb2 Chained Tap Mode

    A “Packetbroker data will be cleared. Go to ATLB2 Mode?” message will be displayed. 4. Select OK. The ATLB2 Chained tap mode will be displayed. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 43: Remove Entity Inline Appliance Member

    If the ports for an entity inline appliance member are configured as packet broker ports they may not be added back to the entity until they are deleted as packet broker ports. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 44: Taps Settings

    When the issue with any entity A, B, C or D inline appliance port(s) is resolved, have link and heartbeats, the tap will automatically switch back to inline. Figure 24 ATLB2 Chained Tap Mode (Inline) Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 45 1-2, 3-4, 5-6 and 7-8 with no regard for the entity inline appliance port(s), link or heartbeats. Typically used during maintenance activities. Figure 26 ATLB2 Chained Tap Mode (Force Bypass) Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 46 The TX will be disabled on all network ports 1-2, 3-4, 5-6 and 7-8. The RX on all network ports 1-2, 3-4, 5-6 and 7-8 remain on. Figure 28 ATLB2 Chained Tap Mode (Reverse Bypass) Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 47: Atlb2 Chained Tap Mode Gui Indications

    5. Entity D’s inline appliance members are normal, have link and heartbeats. The traffic is load balanced across all four members. 6. The traffic per this display indicates: Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 48: Entity Member Abnormal

    Port 1 – Entity A – Entity B – Entity C – Entity D – Port 2 Port 2 – Entity D – Entity C – Entity B – Entity A – Port 1 Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 49: Entity Bypass

    Port 1 – Entity B – Entity C – Entity D – Port 2 Port 2 – Entity D – Entity C – Entity B – Port 1 Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 50: Entity Removed From Chain

    Port 1 – Entity B – Entity C – Entity D – Port 2 Port 2 – Entity D – Entity C – Entity B – Port 1 Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 51: Atlb2 Chained Tap Forced Bypass

    6. The traffic per this display indicates: Port 1 – Port 2 Port 2 – Port 1 Port 3 – Port 4 Port 4 – Port 3 Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 52: Atlb2 Chained Tap Bypass

    5. Entity D’s inline appliance members 33-34, 35-36 and 37-38 are abnormal, loss of link or loss of heartbeats. Entity D is bypassed. Entity D’s bypass threshold is 3. 6. The traffic per this display indicates: Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 53: Packet Broker

    The following configuration options may be displayed, modified, enabled or disabled under the Packet Broker panel. Configuration Maps Load Balance Groups Tunnels Load Balance Policy Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 54: Tunnels

    The Packet Broker Configurations panel will be displayed. Tunnels The system supports the ability to: - Encapsulate VXLAN packets - Decapsulate VXLAN packets - Encapsulate l2GRE packets - Decapsulate l2GRE packets Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 55 4. Add an egress port by placing the cursor on the desired port. Select with the left mouse button. Drag the port to the Egress panel and release. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 56 Decapsulate VXLAN Packets (VXLAN RX Only) When the VXLAN header is decapsulated from a packet, the VXLAN header segments are removed as shown below. VXLAN Encapsulated Packet VXLAN Decapsulated Packet Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 57 4. Add an egress port by placing the cursor on the desired port. Select with the left mouse button. Drag the port to the Egress panel and release. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 58 The vxlan-rx-only tunnel with the Secondary VNID will be displayed on the Tunnels panel. The tunnel may be deleted by selecting the Red X. However, all Secondary VNIDs must be removed first. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 59: Encapsulate L2Gre Packets (Gre Tx Only)

    3. Add an ingress port by placing the cursor on the desired port. Select with the left mouse button. Drag the port to the Ingress panel and release. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 60 15. Select Save. The gre-tx-only tunnel will be displayed on the Tunnels panel. 16. The tunnel may be deleted by selecting the Red X. 17. Select OK. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 61: Decapsulate L2Gre Packets (Gre Rx Only)

    4. Add an egress port by placing the cursor on the desired port. Select with the left mouse button. Drag the port to the Egress panel and release. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 62: Filter Template

    Template options may be modified when applied to a config map. Any option modification made will not change the original template. It is advisable to rename a filter applied to a config map if the original template options were modified. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 63: Load Balancing Group

    Previously created load balancing groups will appear on the Create Config Map panel. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 64: Load Balancing Policy

    The Load Balancing Policy panel will be displayed. 2. Select or deselect the desired load balancing policy options. 3. Select Save to save updates. 4. Select Cancel to disregard changes. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 65 7. Select the Description pencil to apply a description, optional. 8. Enter the desired description. 9. Select the Check to apply. 10. Select the No to disregard. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 66 Figure 30 Filter Figure 31 Filter System Considerations 2. Filter templates may be modified by selecting the green filter icon for the desired template. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 67 Ports may be added or removed from any load balancing group. If ports are added or removed from a previously created load balancing group, the original load balancing group will also be modified. Figure 33 Egress Load Balancing Group Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 68 The filters are considered from top to bottom. A filter may be selected and moved up or down depending on priority preference. Figure 36 Port XX Egress Filters Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 69 The “Save this configuration? (May take a few seconds.)” panel will be displayed. 2. Select OK to save the Config Map. 3. Select Cancel to disregard. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 70 4. Select Refresh Counts to refresh the statistics. 5. Select Clear Counts to clear and refresh the statistics. 6. Select the Egress Filter icon to display the statistics. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 71 2 and finally the Traffic_C is the next priority 3. The Priority of a config map may be changed to a higher or lower value using two methods. Figure 38 Config Map System Considerations Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 72 1. Select the red dash for the config map in the Enable column. The red dash will change to a green check. 2. Select Save. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 73 VLAN Tag Set Speed VLAN Strip Speed Port Statistics 1. Select Port Info on the Dashboard menu bar. The Port Configuration panel will be displayed. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 74 1. Select Port Statistics on the Port Configuration panel. The Port Statistics panel will be displayed. 2. Update the statistics by selecting Refresh. 3. Clear and refresh the statistics by selecting Clear. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 75 The Port Statistics panel displays the following details. The statistics do not automatically update. Port Number Receive Packets Receive Discards Receive Errors Transmit Packets Transmit Discards Transmit Errors Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.
  • Page 76 EdgeLens | INT10G8XX56 | 4.22.1 1. Select Port Statistics. Refresh Statistics 1. Select Refresh to update the statistics. Clear Statistics 1. Select Clear to clear and update the statistics. Garland Technology | 716.242.8500 | www.garlandtechnology.com Copyright © 2022 Garland Technology, LLC. All rights reserved.