Miele KFN 9859 iDE Operating And Installation Instructions page 45

Table of Contents

Advertisement

The outlet must be easily accessible in
an emergency so that the appliance can
be quickly disconnected from the elec-
trical supply in case of an emergency.
The socket must be located so that the
upper edge is a maximum
82" (2100 mm) distance from the upper
edge of the base of the kitchen cabinet.
If the outlet is no longer accessible
once the appliance has been installed,
an all-pole disconnect device with a
contact opening of at least 1/8" (3 mm)
must be present on site. The discon-
nect device may be circuit breaker, a
fuse, or a contactor (compliant with lo-
cal regulations).
The plug and power cord must not
come into contact with the back of the
appliance as vibrations can cause dam-
age to these components. This, in turn,
could result in a short circuit.
Do not plug in other devices behind this
appliance.
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not syn-
chronized with the grid power supply
(e.g., island networks, back-up sys-
tems) is possible. A prerequisite for op-
eration is that the power supply system
complies with the specifications of
EN 50160 or an equivalent standard.
The function and operation of the pro-
tective measures provided in the do-
mestic electrical installation and in this
Miele product must also be maintained
in isolated operation or in operation that
is not synchronized with the grid power
supply, or these measures must be re-
placed by equivalent measures in the
installation. As described, for example,
in the current version of VDE-AR-E
2510-2.
If the power cord needs to be replaced,
this must be done by a qualified techni-
cian.
Installation
45