Step Action
5
Select SIMATIC Manager: "Options > Set PG/PC interface".
The dialog box "Set PG/PC Interface" opens.
Setting the PG/PC interface
6
Select the option "PC internal (local)"as the "Interface Parameter Assignment Used" and click on "OK".
The PG/PC interface is set to "PC internal (local)".
7
Open HW Config again.
Click on "PLC Download".
Select all target modules.
Click "OK".
The download starts. After the download, select "Station > Exit".
Check the configuration in the Station Configuration Editor.
For additional information on setting the PC station as an OS, refer to the PCS 7 Getting
Started manuals.
SIRIUS Motor Starter PCS 7 Library "V7.1+SP2"/ "V8 Migration V8.0+SP1"
Getting Started, 08/2013, A5E02897539020A/RS-AA/005
First steps for the project
2.1 Configuration of PC station
13