Table of contents Contact Details......................2 Important Information..................4 Safety notices in this manual........................4 Safety instructions on the device.......................5 General safety notices............................ 5 Instructions for use / Maintenance......................7 Introduction......................8 Product description............................9 Identification of the product variant......................10 Dimensional drawings and dimensions....................11 Scope of delivery............................12 Available accessories and equipment (optional)................12 Assembly and installation.................13 Requirements for the assembly site.......................13...
Important Information Safety instructions in this manual This instruction manual contains important information for installation and putting into operation of all charging stations of type cPH2. Please make sure to read and follow the provided safety notices in any circumstances. In particular, the warnings and safety measures clearly marked in this manual must be followed.
Installation, commissioning, maintenance and repair of the charging station must only be carried out by qualified personnel. eCharge Hardy Barth GmbH does not assume liability for any damage of property or physical injuries caused by non compliance of the assembly and manual instructions, by usage of non-authorized replacement parts or accessories or by deploying non- qualified professional staff.
Page 6
In case of a substandard installation or a malfunction caused by substandard installation, please contact first the company that has carried out the installation. If the errors still cannot be rectified, please contact the technical support of eCharge. Via Mail support@echarge.de Via phone +49 (0) 9666 –...
Instructions for use / Maintenance Observe the following instructions for use or maintenance of your charging station: • This device must ALWAYS be connected to the protective conductor of the power supply! • Ensure that the rated voltage and current of the device comply with the specifications for your local power grid and that the rated power is not exceeded during charging operation.
With this Wallbox you invest in an innovative and future-proof solution for the private and public sector to charge your electric vehicle reliably and intelligently. The Wallboxes of the cPH2 series are delivered pre-configured for a minimum of technical and temporal installation effort, for an appropriately prepared installation site.
Product description Your cPH2 charging station allows safe and convenient charging of electric vehicles in accordance with the IEC 61851-1 standard, Mode 3. Depending on the variant in question, the cPH2 is always designed for the fastest possible charging of the connected electric vehicles in terms of circuit design, cable diameter and connections.
Identification of the product variant The cPH2 series comprises several variants that differ in terms of charging sockets and charging power and thus serve different application profiles. For identification of the variant, there is a product type plate on the outside and inside of the housing.
The cPH2 Wallbox is delivered fully assembled and tested. All dimensions as well as the mounting points are shown in the following dimensional drawings. Top and side view of the cPH2 series (all dimensions in mm) Installation and operating manual...
Screws and dowels for wall mounting of the Wallbox Available accessories and equipment (optional) eCharge Hardy Barth GmbH offers the following accessories for your cPH2 Wallbox. For more information or information about available accessories and the further delivery program of eCharge, please visit our website at: www.echarge.de...
Assembly and installation Attention Assembly, installation and initial commissioning of the charging station may only be carried out by qualified personnel. The cPH2 Wallbox is an electrotechnical device and is therefore subject to certain specifications for indoor and outdoor installation. Although the housing of the cPH2 complies with the regulations described for protection class IP54, you must take the following environmental conditions into account in particular: •...
• Basically, the cPH2 is designed for operation in high ambient temperatures. Nevertheless, it is recommended to install the charging station, if possible, in a way that it is protected from direct sunlight: this prevents excessive heating of the housing. For more information on environmental conditions, refer to the "Technical data"...
Electrical installation of the charging station DANGER! Danger to life due to electric shock! Before working on the cPH2 charging station: Disconnect the power supply and ensure that it remains permanently disconnected during the work. After completion of the mechanical installation, the charging station is ready to be connected to the mains.
Page 16
Proceed as follows to connect the charging station to the mains: 1 Make sure again that all line circuit breakers and current circuit breakers in the supply line are deactivated. 2 Remove the housing cover of the charging station. 2.1 Unscrew the two screws on the lower side of the lid 2.2 Carefully lift off the housing cover 2.3 Carefully lift off the touch guard and pull out the plug connection of the LED- indicators.
Page 17
Designation Core colour supply line Marking terminal block Live conductor phase 1 BROWN Live conductor phase 2 BLACK Live conductor phase 3 GREY Neutral BLUE Protective conductor GREEN-YELLOW DANGER! The previously mentioned colour coding is NOT international binding: If the individual wires in the supply cable are color-coded differently, contact a qualified electrical specialist company! Have the supply line checked and replaced if necessary.
Commissioning and charging Safety instructions for operation Before you perform a charge with the cPH2, you must check the following points for your safety: • The cPH2 has been installed according to the specifications in this document: In particular, ensure that the charging station is freely accessible, not exposed to direct sunlight or rain if possible, and that an electric vehicle can be connected without the charging cable being under tension or otherwise stressed.
Loading process The cPH2 is designed to charge your vehicle as quickly as possible. However, the effective charging time depends on the vehicle battery, as well as the current residual energy in the vehicle. A binding statement on the charging time is therefore not possible: You can therefore only conclude the actual charging time yourself from your practical experience values.
Page 20
6. Start of the charging process: In the default configuration, the charging process starts immediately after the authentication via RFID card has been successfully performed. When the charging process starts, the color of the status LED of the associated charging socket changes from yellow to blue.
Charge control With the upgrade to our "Salia" board, all cPH charging stations of the 2 series get a number of additional functions. While one or more vehicles are in a charging phase, the charging current for each charging point can be actively controlled in real time. For various applications, it may also be useful to specify the maximum or minimum current of the charging process.
The RFID module is integrated into the touch protection cover together with the optical RGB LED and connected to the Wallbox via a plug connection. This can be disconnected for installation or maintenance of the charging station. Please ensure that the plug connection is made at the touch guard during normal operation and function testing! Further information on the charging process can be found on page 19.
Malfunctions and solutions The cPH2 performs various internal test routines to ensure proper and safe operation. In order to take appropriate measures in the event of a fault and to restore operation, you must first establish beyond doubt what type of fault is present. DANGER! Life-threatening voltages occur inside the charging station! Opening and subsequent work on the charging station may only be...
Technical data Supply / Charge Type 1T11 1T22 2T22 2T44 1x Terminal block, 5 x 6 mm 2x Terminal block, 5 x 6 mm Connection terminals (L1,L2,L3,N,PE) (L1,L2,L3,N,PE) Rated voltage / frequency 230 V | 400 V 3-phase; 50 Hz Rated current 16 A 32 A...
Page 25
Functions / Fixtures RGB LED's for operating state Energy meter MID compliant, per charge point Load management dynamically between the charging points Power control adjustable via web interface, 6 A - 32 A PV control with compatible system RFID Mifare DESFIRE, (ISO14443A+B) and LEGIC Prime & Advant Authentication (optional) Charge release (optional) local RFID, keyswitch, Whitelist, OCPP 1.6...
Standards & Guidelines The cPH2 charging station complies with the following standards and protection classes: General standards Norm Explanation 2014/30/EU EMC Directive 2011/65/EU RoHS Directive 2012/19/EU WEEE Directive ElektroG Electrical and Electronics Act Standards, protection class and degree of protection for device safety DIN EN IEC 61851 describes conductive charging systems for electric vehicles: Norm Explanation...
Warranty / Guarantee Warranty and guarantee condition eCharge Hardy Barth GmbH grants the legally prescribed warranty period of 24 months on the present product as well as a warranty with the same duration for the country in which the product was purchased.
Page 28
Under no circumstances should you make any changes or repairs to your product yourself! The company eCharge Hardy Barth GmbH assures the proper operation of the present product after delivery within the scope of the legally valid warranty. The warranty is limited to such damage that is due to normal use and obvious material or manufacturing defects.