Hardy Barth cPm1 Instruction Manual
Hide thumbs Also See for cPm1:

Advertisement

Quick Links

Charging Station
cPµ1
Instruction Manual
Instruction Manual
cPµ1
charging station
1
Version: 1.3.5

Advertisement

Table of Contents
loading

Summary of Contents for Hardy Barth cPm1

  • Page 1 Charging Station cPµ1 Instruction Manual Instruction Manual cPµ1 charging station Version: 1.3.5...
  • Page 2: Contact Details

    Contact Details eCHARGE Hardy Barth GmbH Manufacturer Leinbergstraße 14 92262 Birgland-Schwend Germany Phone: +49 (0) 9666 188 1350 Fax: +49 (0) 9666 188 1351 Web: www.echarge.de E-Mail: support@echarge.de cPµ1 Instruction Manual charging station Version: 1.3.5...
  • Page 3: Table Of Contents

    Contents Contact Details......................2 Important Informa on....................4 Safety no ces in this manual......................4 Safety no ces on this device......................5 General safety no ces........................5 Opera ng instruc ons/Maintenance....................7 Dimensional drawings and measurements..............9 Introduc on......................10 Product descrip on........................11 Iden fying your product variant....................11 Scope of delivery..........................12 Available accessories........................12 Preparing the installa on..................13...
  • Page 4: Important Informa On

    Important Information Safety notices in this manual This instruction manual contains important information for installation and putting into operation of all charging stations of type cPµ1. Please make sure to read and follow the provided safety notices in any circumstances. In particular, the warnings and safety measures clearly marked in this manual must be followed.
  • Page 5: Safety No Ces On This Device

    Safety notices on this device Further safety notices and operating instructions can be found on and also inside the device. These symbols carry the following meanings: General safety notices Before you start operating your cPµ1 charging station, please make sure you have carefully read the manual, heeded and followed all instructions and warnings.
  • Page 6 In case of a substandard installation or a malfunction caused by substandard installation, please contact first the company that has carried out the installation. If the errors still cannot be removed, please contact the technical support of e C H A R G E H a r d y B a r t h G m b H Via email support@echarge.de Via telephone...
  • Page 7: Opera Ng Instruc Ons/Maintenance

    Operating instructions/Maintenance Please note the following instructions regarding usage and maintenance of your device: • This device MUST ALWAYS be connected to the protective conductor of the power supply. • Please ensure that the rated nominal voltage and rated nominal current of the device correspond with the requirements of your local power supply system and that the nominal capacity is not exceeded during charging.
  • Page 8 • Regularly examine the charging cable and/or charging sockets of your Wallbox as well as additional accessories to find possible damage spots and/or damages in general. If damages are found on the additional charging cable, please replace them immediately. No further charging is allowed in this case. DANGER! If you find damage on the housing, charging sockets or corresponding charging cables after installation, take the Wallbox out of order...
  • Page 9: Dimensional Drawings And Measurements

    Dimensional drawings and measurements The cPµ1 charging station is delivered after being completely assembled and tested. Below, all measurements and assembly points are detailed in the dimensional drawings. Charging station Front view and side view of the cPµ1-series (all specifications are in mm) Instruction Manual cPµ1 charging station...
  • Page 10: Introduc On

    Introduction Thank you for choosing the cPµ1 charging station by e C H A R G E By choosing this product, you are investing in an innovative and sustainable solution for the public and industrial section. The charging stations of the cPµ-series are delivered pre-configured and can be installed at a prepared mounting site with minimal technical and minimal time effort.
  • Page 11: Product Descrip On

    Product description Your cPµ1 charging station permits safe and comfortable charging of electric vehicles according to Norm IEC 61851-1, Mode 3. Depending on the respective variant your cPµ1 is laid out for charging as fast as possible due to its circuit design and its diameter of cables and pins. The cPµ1 also offers a fixed charging cable according to IEC 62196-2 of either Type 1 or Type 2, depending on your variant.
  • Page 12: Scope Of Delivery

    Scope of delivery Your cPµ1 Wallbox is delivered with various components which are essential for the installation and proper operation. Please check immediately whether your package contains the following basic components: Components Quantity Description cPµ1 charging station 1 Charging station consisting of plastic housing with a lockable cover Instruction for assembly 1 Contains instructions for mechanical and...
  • Page 13: Preparing The Installa On

    Preparing the installation Several requirements regarding the mounting site and connection technology must be met for the installation in order to guarantee a safe operation. Requirements for mounting site The cPµ1 charging station was developed for indoor as well as outdoor areas. As user, please note the following requirements for the mounting site and installation to ensure safe charging later on.
  • Page 14: Installa On And Taking Into Opera On

    Installation and taking into operation The installation has to be carried out principally by professional staff. Approval has to be given by a qualified electric company before the charging station can be taken into operation for the first time. The cPµ1 charging station is an electrotechnical device and therefore has to follow certain demands concerning the installation indoors and outdoors: Even though the housing of the cPµ1 fullfills the standards given by IP44, please note, especially for outdoors, various environmental conditions:...
  • Page 15: Mechanical Installa On On Wall

    Mechanical installation on wall At least two persons are required to perform the following instructions. Additionally these components will be required: • An electric drilling machine or a cordless screwdriver (not included in scope of delivery) • A twist drill Ø 6 mm for the respective mounting surface (not included in scope of delivery) •...
  • Page 16: Electrical Installa On Of Charging Sta On

    Electrical installation of charging station DANGER! Danger to life due to electric shock! Before working with the cPµ1 charging station: Disconnect the electrical power supply and make sure that it stays disconnected non-stop through the whole installing process. After completion of the mechanical installation the charging station will be connected to the power line.
  • Page 17 Description Colour of core Label Live conductor Phase 1 BROWN L1 (brown leakage) Live conductor Phase 2 BLACK L2 (black leakage) Live conductor Phase 3 GREY L3 (grey leakage) Neutral BLUE N (blue leakage) Protective conductor GREEN-YELLOW GREEN-YELLOW LEAKAGE DANGER! The previously named colour codes are NOT obligatory on an international level: If the cores are colour-coded differently please contact a qualified electrical company and have them examine the lead...
  • Page 18: Taking Into Opera On And Charging Process

    Taking into operation and charging process After the mechanical and the electrical installation, your charging station is immediately ready. The cPµ1 possesses a Type 1 or Type 2 charging cable complying with IEC 62196-2 for charging (depends on variant). The Type-2 charging cable of the cPµ1 has three live conducting pins, a neutral conductor, a PE conductor and two signalling contacts (Control Pilot and...
  • Page 19: Safety No Ces For Opera On

    Safety notices for operation Please note the following safety notices before you charge with your cPµ1: • Make sure that the cPµ1 has been installed according to the requirements of this document. Mind especially that the charging device is freely accessible and is not exposed to rain or direct solar radiation.
  • Page 20: Charging Process

    Charging process The cPµ1 is designed to charge your vehicles as fast as possible according to IEC 61851-1 Mode 3. The effective charging time depends on the battery of your vehicle as well as on the current residual energy. Therefore, it is not possible to give a binding statement regarding the charging time.
  • Page 21: Troubleshoo Ng

    Troubleshooting The cPµ1 is also designed for maximum security and reliable charging. Through internal testing routines, malfunctions are identified and immediate switch off is issued. Should there be any malfunctions during the charging process, the LED- Display will immediately indicate them. This chapter describes how to recognize the error states and operating states and which measurements are to take in order to repair the glitch.
  • Page 22: Interrup Ons Of Opera On And Solu Ons

    Interruptions of operation and solutions The cPµ1 executes internal testing routines to guarantee proper and safe operation. In order to restore the previous operation state, first, it is essential that you determine the type of malfunction undoubtedly. DANGER! Inside the charging station life threatening voltages occur! Opening the charging station and following works on the charging station must be carried out solely by qualified staff.
  • Page 23: Appendix

    Appendix Technical specifications Variant cPµ1 Power line For lead up to. 5×4 mm² at maximum Rated nominal voltage 230 / 400 V Rated nominal current 16 A / 20 A, 3-phase / 1-phase Nominal frequency 50 Hz Maximum charging capacity 11 kW DC fault current detection 6 mA (built in);...
  • Page 24: Standards And Guidelines

    Standards and guidelines The cPµ1 fullfills the following standards and protection classes: General standards Norm Explanation 2014/30/EU EMV-guideline 2011/65/EU RoHS-guideline 2012/19/EU WEEE-guideline ElektroG Electrical and electronical laws Equipment safety standards Norm Explanation Conductive charging systems for electric vehicles IEC 61851-1 Ed 2.0:2010 part 1: general requirements Conductive charging systems for electric vehicles IEC 61851-22 (69/201/CD)
  • Page 25 Protection class and protection types Protection class/protection type Explanation Protection class I: all electrically conductive components of the operating device are connected low impedance with the protective conductor system of the fixed installation Protection type of housing: Protection against foreign objects < 1 IP 44 mm and protection against splashing from every direction...
  • Page 26: Warranty / Guarantee

    Warranty / Guarantee Guarantee specifications and warranty eCHARGE Hardy Barth GmbH guarantees the legally prescribed warranty period of 24 month for the present product as well as a warranty of the same duration for the country in which the product was purchsaed.
  • Page 27 Do not, under any circumstances, make alterations or repairs to your product on your own! The company eCHARGE Hardy Barth GmbH guarantees the proper operation of the present product after delivery within the scope of the lawfully valid warranty. The warranty is limited to such damage that is attributable to normal use and to obvious material or manufacturing defects.

Table of Contents