Injections by high-pressure fluid discharge. Before selecting or using any of these Products, it is important that you read and follow the instructions below. Only Hose from Parker’s Stratoflex Products Division is approved for in flight aerospace applications, and no other Hose can be used for such in flight applications.
INSPECTION – Visually inspect all components for shipping damage. If any shipping damage is found, notify the carrier at once. Shipping damage is not covered by the Parker warranty. The carrier is responsible for all repair and replacement costs resulting from such damage.
Note: Cycle times vary depending on hose and fitting styles and sizes. Model Numbers Figure 1: PHastkrimp Crimping Machine 89C-061 includes: PHastkrimp crimper with 230VAC, 3 phase, 60 Hz power unit. • Die Ring Silver 85C-R01 • Die Ring Black 85C-R02 •...
10. Wire the machine in accordance with the requirements of the National Electrical Code. Caution: Check for proper motor rotation per page 4. Removal of Air from the PHastkrimp Hydraulic Circuit The hydraulic system, when connected for the first time, will have air in the system. The air must be removed for safety and proper operation.
PHastkrimp Crimper Electrical Requirements, 3 Phase The power supply should be brought to a separate branch circuit, single-grounded receptacle. The PHastkrimp unit has been shipped with a 6 ft. long cord without a plug. Machine is shipped without a plug so local requirements may be satisfied.
PHastkrimp Crimper Electrical Requirements, 1 Phase The power supply should be brought to a separate branch circuit, single-grounded receptacle. The PHastkrimp unit has been shipped with a 6 ft. long cord without a plug. Machine is shipped without a plug so local requirements may be satisfied.
Bulletin 4480-T15-US Crimping Machine Operations and Crimping PHastkrimp The following crimping dies are available for use with the PHastkrimp machine: 26 Series Fitting Dies (Silver) 43 Series Fitting Dies (Silver) 80C-E04 Size -4 (3/16") Color Coded Red 80C-A04 Size -4 (1/4")
If you find your crimp diameters out of tolerance, inspect each assembly made. Never allow hose assemblies with an incorrect crimp diameter to be used. Use the appropriate Parker Machine Trouble Shooting Guide to determine the cause. If you are unable to determine the cause of the problem, call our Hose Products Division Technical Service Department, (440) 943-5700, for assistance.
Important: Hose assemblies must be inspected for cleanliness and free of all foreign particles. 13/16" 13/16" 13/16" 15/16" Note: Parker Hannifin will not accept responsibility for the 13/16" 1-1/8" 1-1/16" 1-1/16" operation of, or provide warranty coverage for, a crimper 13/16" 1-5/16" 1-5/16"...
PHastkrimp If you have a problem with your PHastkrimp machine: • First check that the proper tooling, hose and fitting combinations are being used as identified in the Parker Catalog 4400. • Then check the following recommendations. If after the following suggested remedy, the problem persists, call our Technical Service Department at (440) 943-5700.
Page 17
Parker Catalog 4400. Wrong hose being used Use only Parker No-Skive hose. For a complete selection of hose and fittings, see Parker Catalog 4400. Wrong die ring being used See crimper decal or Parker Catalog 4400 for correct die ring.
• Apply approved grease to the dies and crimp bowl each time the dies are changed. If dies are not changed through a day's operation, grease should be applied twice a day. Parker Hannifin Corporation Hose Products Division Wickliffe, OH...
• Injuries resulting from inhalation, ingestion or exposure to fluids. Before selecting or using any of these Products, it is important that you read and follow the instructions below. Only Hose from Parker’s Stratoflex Products Division is approved for in flight aerospace applications, and no other Hose can be used for such in flight applications.
Page 20
Hose for in flight applications is available only from Parker’s Stratoflex Products snagging, kinking, bending smaller that minimum bend radius, and cutting, any Division. Do not use any other Parker Hose for in flight applications, even if of which can cause premature Hose failure. Any Hose that has been kinked or electrically conductive.
Page 21
Reusable/Permanent: Do not reuse any field attachable (reusable) hazardous areas while testing and using the system. See section 2.2. Hose Fitting that has blown or pulled off a Hose. Do not reuse a Parker permanent Replacement Intervals: Hose assemblies and elastomeric seals used Hose Fitting (crimped or swaged) or any part thereof.
The items described in this document and other documents or descriptions provided by Parker Hannifin Corporation, as subsidiaries and its authorized distributors are hereby offered for sale at prices to be established by Parker Hannifin Corporation, its subsidiaries and its authorized distributors. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions.