Settings - Filter/Maintenance Reminders; Settings - Balance Point - Lennox ComfortSense 3000 Series Operation Manual

Programmable thermostat
Hide thumbs Also See for ComfortSense 3000 Series:
Table of Contents

Advertisement

If auto fan mode is selected (AUTO displayed in FAN box
- see figure 14), the fan will only run when the heating or
cooling equipment is running.
Figure 17. Using Fan AUTO

SETTINGS - Filter/Maintenance Reminders

The L3532H thermostat is designed to remind you when
the filter needs changing or when routine maintenance
is required, as (and if) defined, by you. These optional
reminders are not enabled until you activate them. To do so,
press the Settings button (shown below the Fan button in
figure 17) once or twice for the desired reminder as shown
in figure 18 and as described in table 1.
Figure 18. Reminder Settings Display
The default setting for the reminders is OFF (disabled).
Press Up/Down arrow buttons to select the desired reminder
intervals.
Table 1. Filter and Maintenance Reminders
Buttons to
Use
Settings
(1st press)
then Arrows
to scroll
selections
Settings
(2nd press)
then Arrows
to scroll
selections
Enter
NOTE: The HOME screen will reappear about 15 seconds
after the final arrow button press. OR, press ENTER
Available Settings
and
Reminder
How to Use
Total fan run time
expressed in months
(Off, 1, 3, 6, 12);
for example, if fan
FILTER
runs 12 hours a day,
1 month reminder
displays in 2 calendar
months
Elapsed chronological
time in months (Off,
6, 12). Use this, for
example, to remind
yourself when to
MAINT
perform routine
checks or when to
call a technician for
periodic preventive
maintenance.
Stores settings.
at any time to store any changes and exit to the
HOME screen.
After either programmed interval has elapsed, the reminder
will be displayed as shown in figure 19.
Figure 19. Reminders
After the filter has been changed, reset the filter reminder by
pressing the SETTINGS button for 4 seconds. The screen
will blink for a few moments to indicate that the timer has
been reset.

SETTINGS - Balance Point

NOTE: NOTE - The balance point is only available with the
outdoor sensor.
If the optional outdoor sensor (X2658) is connected to
the thermostat, balance point adjustment is available.
The balance point feature allows the measured outdoor
temperature to govern operation of the heat pump and
backup heat source.
Use the SETTINGS button to access the balance point
setting. If the outdoor sensor is attached to the thermostat,
press the SETTINGS button three times to access the
Balance Point Settings screen (see figure 20).
Figure 20. Balance Point Settings
The balance point can be set at any temperature between
1°F and 55°F (-17°C to 13°C). A balance point setting of
zero disables the balance point function (in this case, the
thermostat behaves as if no outdoor sensor is attached).
The default balance point setting is 55°F. To adjust the
balance point up or down, press the Up/Down arrow buttons
to the right of the display screen. The balance point setting
increases by 1°F each time the Up button is pressed and
decreases by 1°F each time the Down button is pressed.
After the desired balance point is reached, the HOME
screen will reappear after about 15 seconds.
NOTE: The balance point feature allows the outdoor
temperature to rise or fall 3°F above or below the
balance point. This prevents excessive cycling of
the equipment when the outdoor temperature is
near the balance point. For example, if the balance
6