Marvel 60RGD-SS-F Installation, Operation And Maintenance Instructions

Marvel 60RGD-SS-F Installation, Operation And Maintenance Instructions

Refrigerated drawer

Advertisement

MARVEL REFRIGERATED DRAWERS
Installation
Operation
and
Maintenance
Instructions
Refrigerated Drawer Models
60RDE
80RDE
6ORDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 60RGD-SS-F and is the answer not in the manual?

Questions and answers

Summary of Contents for Marvel 60RGD-SS-F

  • Page 1 MARVEL REFRIGERATED DRAWERS Installation Operation Maintenance Instructions Refrigerated Drawer Models 60RDE 80RDE 6ORDE...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Unpacking your refrigerated drawer unit...2 Removing the packaging...2 Warranty Registration...2 Installing your refrigerated drawer unit...3 Selecting the location...3 Outdoor Installation...3 Cabinet Clearances...3 Leveling legs...3 Grounding method...3 Electrical Requirements...3 Installing the anti tip device..4 Dimensions Indoor Model 60RDE... 5 Recommended Rough in Opening Dimensions Indoor Model 60RDE...
  • Page 3: Unpacking Your Refrigerated Drawer Unit

    MANUFACTURER - FILE THE CLAIM WITH THE RETAILER. If the unit was shipped or has been laying on its back for any period of time allow the refrigerator to sit upright for a period of at least 24 hours before plugging in. This will assure oil returns to the compressor.
  • Page 4: Installing Your Refrigerated Drawer Unit

    For this reason it is important this area to not be obstructed and be kept clean.Marvel does not rec- ommend the use of custom made grilles as air flow may be restricted because of inadequate openings.
  • Page 5: Installing The Anti Tip Device

    Anti - Tip Device A cabinet “anti–tip” device is mounted to the back of your refrigerated drawer unit. If your installation is a built – in undercounter application with a countertop directly above the unit this item can be removed, it does not need to be applied.
  • Page 6: Dimensions Indoor Model 60Rde

    Dimensions Indoor Model 60RDE 23-7/8” (60.7 cm) 34-1/4” to 34-1/2” (87 to 87.6 cm) Recommended Rough In Opening Dimensions, Indoor Model 60RDE *Depth dimension may very depending on each individual installation. 26-3/8” (67 cm) 24-1/4” (61.6 cm 22” (55.9 cm) Drawer fully opened 46”...
  • Page 7: Dimensions Indoor Model 60Rde Overlay Door

    23-7/8” (60.7 cm) 34-1/4” to 34-1/2” (87 to 87.6 cm) Recommended Rough In Opening Dimensions, Indoor Model 60RDE Overlay Door (87.6 cm) *Depth dimension may very depending on each individual installation. Dimensions for Indoor Model 60RDE Overlay Door 23-3/8” (59.4 cm) Drawer fully opened Not including 45-1/8”...
  • Page 8: Dimensions Outdoor Model 6Orde

    A ground fault circuit interrupter electrical receptacle is to be used to supply electrical power to the refrigerator for outdoor applications. Contact an electrician if you need to install one to supply electrical power to your outdoor refrigerator. Product weight = 170 lbs. (77.1 kg.)
  • Page 9: Dimensions Indoor Model 80Rde

    29-7/8” (75.9 cm) 34-1/4” to 34-1/2” (87 to 87.6 cm) Recommended Rough In Opening Dimensions, Indoor Model 80RDE *Depth dimension may very depending on each individual installation. Dimensions for Indoor Model 80RDE 26-3/8” (67 cm) 24-1/4” (61.6 cm 22” (55.9 cm) Drawer fully opened 46”...
  • Page 10: Dimensions Indoor Model 80Rde Overlay Door

    Dimensions for Indoor Model 80RDE Overlay Door 29-7/8” (75.9 cm) 34-1/4” to 34-1/2” Recommended Rough In Opening Dimensions, Indoor Model 80RDE Overlay Door *Depth dimension may very depending on each individual installation. (87 to 87.6 cm) Drawer fully opened Not including 45-1/8”...
  • Page 11: Full Overlay Panel Installation Instructions

    FOR MODELS 60RDE and 80RDE WITH OVERLAY PANELS Figure 6 Figure 5 Figure 7 Gasket Figure 8 INSTALLATION INSTRUCTIONS Determine Wood Screw Requirements A #8 pan head wood screw should be used to prop- erly secure the overlay panel. A total of 8 screws per drawer for the 60 unit and 10 screws per drawer for the 80 unit will be required.(See Figure 9).
  • Page 12: Full Overlay Panel Installation Instructions

    FULL OVERLAY PANEL INSTALLATION INSTRUCTIONS Step 2: Size the Overlay Panel Cut the overlay panel to the dimensions shown below. Use Figure 10 for the 60RDE Drawer, and Figure 11 for the 80RDE drawer. Panel thickness 23.63” (600.2 mm) 15.19” (385.83 mm) Figure 10 Face of 60RDE...
  • Page 13: Using Your Refrigerated Drawers

    Load Your Appliance Load your appliance with your desired items. Please note that it may take up to 24 hours for your refrigerator to reach the desired temperature once loaded. This will pri- marily depend on the amount of contents loaded into the refrigerator and the amount of opening and closings of the drawers.
  • Page 14: Using Your Refrigerated Drawers

    USING YOUR REFRIGERATED DRAWERS Figure 14 Warning Alarms The Sentry System™ monitor will let you know if your unit is not functioning properly for the following reasons. Door ajar, high or low temperature, and power failure. These alarms are explained below. Door Ajar Alarm If the drawer has been left open for over five (5) minutes, the alarm will sound and the LED will flash green.
  • Page 17: Care And Cleaning

    The painted cabinet can be washed with either a mild soap and water and thoroughly rinsed with clear water. NEVER use abrasive scouring cleaners. AVAILABLE OPTIONS FOR YOUR MARVEL DRAWER REFRIGERATOR E-Z Stor Storage System Removable stainless steel bins with clear plastic lids can be moved to prep, cook, or serving areas as desired.
  • Page 18: Troubleshooting Guide

    If Service is Required: • If the product is within the first year warranty period please call Marvel Customer Service at 800.223.3900 for directions on how to obtain warranty coverage in your area. •...
  • Page 19: Household Product Warranty

    Entire Product Limited One Year Parts and Labor Warranty Marvel warrants that it will supply all necessary parts and labor to repair or replace in the end user’s home or office, any component which proves to be defective in material...
  • Page 20 Northland-Marvel P .O. Box 400 1260 E. Van Deinse St. Greenville MI 48838 800.223.3900 41011754-EN Rev H 11/10/09 www.marvelrefrigeration.com All specifications and product designs subject to change without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, replacements or compensation for...

This manual is also suitable for:

80rde60rde6orde6ordessb

Table of Contents