Download Print this page
Haier AB25S2PC1FA Operation Manual And Installation Manual

Haier AB25S2PC1FA Operation Manual And Installation Manual

Cassette type air conditioner

Advertisement

Quick Links

AB25S2PC1FA
AB35S2PC1FA
AB50S2PC1FA
AB71S2PC1FA
0150557263
Cautions ---------------------------------------
Safety Precaution----------------------------
Remote Controller Operation Manual--
Troubleshooting -----------------------------
Customer Need-to-know ------------------
Maintenance ---------------------------------
Installation Procedure ---------------------
Operation-------------------------------------- 24
4
10
11
13
15
16
17

Advertisement

loading

Summary of Contents for Haier AB25S2PC1FA

  • Page 1 Cautions --------------------------------------- Safety Precaution---------------------------- Remote Controller Operation Manual-- AB25S2PC1FA Troubleshooting ----------------------------- Customer Need-to-know ------------------ AB35S2PC1FA Maintenance --------------------------------- Installation Procedure --------------------- AB50S2PC1FA Operation-------------------------------------- 24 AB71S2PC1FA 0150557263...
  • Page 3 Read the precautions in this manual This appliance is filled with R32. carefully before operating the unit. Service indicator; Read technical Read the operator's manual manual The installation and service of this product shall be carried out by professional personnel, who have been trainedand certified by national training organizations that areaccredited to teach the relevant national competency standards that may be set in legislation.
  • Page 4 •A brazed, welded, or mechanical connection shall be made before opening the valves to permit refrigerant to flow between the refrigerating system parts. A vacuum valve shall be provided to evacuate the interconnecting pipe and/or any uncharged refrigerating system part. •The maximum working pressure is 4.3 MPa.
  • Page 5 China GWP:675 f the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Page 6 The specification of power cable is HO5RN-F3G 4.0mm . The specification of cable between indoor unit to outdoor unit is HO5RN-F4G 2.5mm...
  • Page 7 Cautions - The installation of pipe-work shall be kept to a minimum. - Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than Amin(2m2). - Compliance with national gas regulations shall be observed. - Mechanical connections shall be accessible for maintenance purposes.
  • Page 8 Cautions Checks to electrical devices - Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
  • Page 9 Cautions - Become familiar with the equipment and its operation. - Isolate system electrically. - Before attempting the procedure, ensure that: • mechanical handling equipment is available, if required, for handling refrigerant cylinders; • all personal protective equipment is available and being used correctly; •...
  • Page 12 Safety Precautions Installation Precautions Minimum Room Area...
  • Page 13 Remote Controller Operation Manual 4. QUIET Press Remote Controller function description This remote Controller is a general remote Controller, and some functions are valid according Note: This function is valid under the mode of COOL and HEAT. to the adaptable model. 5.
  • Page 14 Remote Controller Operation Manual Functional description Functional description 12. 2. Press the button under the starting state of the remote (1) 1) When the controller is switched on, pr button, control to enter the TIMER OFF health function is activated and the the initial default value is: 12:00.
  • Page 17 -/*, + / ,- .
  • Page 20 AB25S2PC1FA AB35S2PC1FA AB50S2PC1FA AB71S2PC1FA AB25S2PC1FA AB35S2PC1FA AB50S2PC1FA AB71S2PC1FA =]ghUbWY VYhkYYb gigdYbX]b[ Vc`hg /-/aa BbXccf ib]h /1*aa <Y]`]b[ cdYb]b[ 590 aa HfbUaYbh dUbY`620 aa...
  • Page 21 AB25S2PC1FA AB35S2PC1FA PB-620KB AB50S2PC1FA AB71S2PC1FA PB-950KB...
  • Page 23 Pipe size Mod e Liquid side Gas side AB25S2PC1FA Ø 6.35mm Ø 9.52mm AB35S2PC1FA Ø Ø AB50S2PC1FA 6.35mm 12.7mm Ø Ø AB71S2PC1FA 9.52mm 15.88mm...
  • Page 24 AB25S2PC1FA AB35S2PC1FA AB50S2PC1FA AB71S2PC1FA...
  • Page 26 Operation Wi-Fi The system architecture diagram The application environment Smart mobile phone and wireless router are necessary for the appliacation. Wireless router must be able to connect to the Internet. Smart mobile phone requires IOS or Android system: IOS system Android system must support IOS 9.0 or above must support Android 5.0 or above...
  • Page 28 Address: Haierl ndustrial Park, Qianwangang Road, Eco-Tech Development Zone, Qingdao266555, Shandong, China. Contacts: TEL +86-532-88936943; F26 AX +86-532-8893-6999 Website: www.haier.com...