WARNINGS

• Read all instructions before starting to install fixtures.
• Retain these instructions for future reference.
• This product is for installation indoors only.
• DANGER - RISK OF FIRE, INJURY AND DEATH. This fixture must be installed in
accordance with local electrical codes and ordinances. All work must be done by a qualified
electrician.
• DANGER – RISK OF FIRE, INJURY AND DEATH. Make certain power is OFF from the
electrical panel before starting installation or attempting any maintenance.
• DANGER RISK OF FIRE INJURY AND DEATH. Do not damage insulation on wires. Do not
expose wires to sharp edges or objects.
• Secure and protect incoming supply wire and any control wire with a suitable cable restraint
(supplied by installer).
• Only supply voltage as labeled on the product.
• Fixture must be properly grounded.
• Do not install if any part appears to be damaged.
• This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.
• Note: This equipment has been tested and found to comply with the limits for a Class B
digital device , pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation . If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
in encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different for that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
• Conforme.CAN ICES-005 (B) / NMB-005 (B)
2/28/2022
2/28/2022
page
1
1
www.lightolier.com
IS‐MD1R
Mini Downlight
Instructions for Installation and Operation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LIGHTOLIER IS-MD1R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SIGNIFY LIGHTOLIER IS-MD1R

  • Page 1 Classified IS‐MD1R Mini Downlight Instructions for Installation and Operation WARNINGS ⚠ • Read all instructions before starting to install fixtures. • Retain these instructions for future reference. • This product is for installation indoors only. • DANGER - RISK OF FIRE, INJURY AND DEATH. This fixture must be installed in accordance with local electrical codes and ordinances.
  • Page 2 Classified IS‐MD1R Mini Downlight installation STEP 1 Confirm that there is no electrical power on the circuit where the luminaire will be  connected. STEP 2 Use the Installation template provided to make the hole in the ceiling, if needed you  can use the dimensions provided below for different size luminaires: 3‐inch round.         Ø3”(78mm) 4‐inch round Ø4‐1/4”(108mm) 4‐inch square         Ø4‐1/4”(108mm) 6‐inch round Ø6‐1/4”(158mm)  6‐inch square         Ø6‐1/4”(158mm) 8‐inch round          Ø8‐1/4”(210mm)  2/28/2022 page www.lightolier.com...
  • Page 3 Classified IS‐MD1R Mini Downlight STEP 3 Open the splice box cover and only remove the knockout needed. Incoming wires  must be secured with an appropriate restraint (provided by installer).  STEP 4 Secure the splice box to the building structure in accordance with applicable codes.  WARNING – Attach the Driver/Splice Box to a secure structural part of the building  per applicable codes. Use optional 10 foot long extension cord (sold separately) if  additional cord length is needed. Only one extension cord may be used with each luminaire. 2/28/2022 page www.lightolier.com...
  • Page 4 Classified IS‐MD1R Mini Downlight Driver Wiring STEP 5 WITH THE POWER OFF, make electrical connections as shown in  Fig 1 below.  WARNING RISK OF FIRE, INJURY AND DEATH. Use wire nuts provided which  are thermally rated for use in a luminaire splice compartment. Box must be  grounded. Note: Select and adjust Lumen and Color settings (where provided) BEFORE installing the  luminaire into the ceiling. STEP 6 Carefully place all wiring into the splice box and close the cover. WARNING Risk of Fire ‐ Be careful not to crush or cut wires when closing the  splice box cover. 2/28/2022 page www.lightolier.com...
  • Page 5 Classified IS‐MD1R Mini Downlight STEP 7 Select desired  the color temperature and lumen output with the  switches (see image below) BEFORE installing in the ceiling. STEP 8 Place the cord from the Driver/Splice box through the opening in the ceiling and  connect it to the cord from the fixture by inserting connectors (1 &2) and then  securing them together using the threaded collar. *Note: Select Lumen and Color settings (where provided) BEFORE installing the luminaire  into the ceiling. 2/28/2022 page www.lightolier.com...
  • Page 6 Classified IS‐MD1R Mini Downlight STEP 9 Hold the luminaire to insert one spring through the ceiling hole and then bend the  other spring upward to insert it through the hole.  *Note: Use supplied gasket when  needed for air seal. WARNING Risk of Fire ‐ Be careful not to crush or cut cord when routing cord from  driver to luminaire  2/28/2022 page www.lightolier.com...

Table of Contents