Direct Venting; Removal Of Existing Furnaces From Common Vent Systems - Bryant H Series Installation, Start-Up, And Operating Instructions Manual

Deluxe 4–way multipoise fixed-capacity direct-vent condensing gas furnace
Table of Contents

Advertisement

VOLTS—
UNIT
HERTZ—
SIZE
PHASE
024040
115-60-1
036040
115-60-1
024060
115-60-1
036060
115-60-1
048060
115-60-1
036080
115-60-1
048080
115-60-1
060080
115-60-1
048100
115-60-1
060100
115-60-1
060120
115-60-1
060140
115-60-1
* Permissible limits of voltage range at which unit will operate satisfactorily.
† Unit ampacity = 125 percent of largest operating component's full load amps plus 100 percent of all other potential operating components' (EAC, humidifier, etc.) full load
amps.
‡ Length shown is a measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.
** Time-delay type is recommended.
ELECTRIC
DISCONNECT
SWITCH
Fig. 28—Disconnect Switch and Furnace
NOTE: A field-supplied, 115-v controlled relay connected to
EAC terminals may be added if humidifier operation is desired
during blower operation.
IX. DIRECT VENTING
The 350MAV Furnaces require a dedicated (one 350MAV furnace
only) direct-vent system. In a direct-vent system, all air for
combustion is taken directly from outside atmosphere, and all flue
gases are discharged to outside atmosphere.
A. Removal of Existing Furnaces from Common
Vent Systems
When an existing Category I furnace is removed or replaced, the
orginal venting system may no longer be sized to properly vent the
TABLE 4—ELECTRICAL DATA
OPERATING
VOLTAGE RANGE
Max*
Min*
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
COPPER
WIRE ONLY
ALUMINUM
WIRE
A93033
MAX
UNIT
UNIT
AMPACITY†
AMPS
6.1
8.4
7.3
10.0
6.1
8.4
7.1
9.8
9.5
12.8
7.6
10.4
10.0
13.4
14.1
18.4
10.2
13.5
14.8
19.3
14.6
19.1
14.3
18.8
ALTERNATE
FIELD
LOCATION
remaining attached appliances. An improperly sized Category I
venting system could cause the formation of condensate in the
furnace and vent, leakage of condensate and combustion products,
and spillage of combustion products into living space, etc.
—21—
MIN
MAX WIRE
WIRE
LENGTH
SIZE
(FT)‡
14
44
14
37
14
44
14
38
14
29
14
36
14
28
12
31
14
27
12
30
12
30
12
30
Fig. 29—Relocating J-Box
MAX FUSE
OR CKT BKR
AMPS**
15
15
15
15
15
15
15
20
15
20
20
20
FACTORY
INSTALLED
LOCATION
A00212