pleasant hearth VFF-PH20LPB Manual

pleasant hearth VFF-PH20LPB Manual

Vent-free gas fireplace
Table of Contents

Advertisement

WARNING: This appliance
is equipped for (Natural or Pro-
pane) gas. Field conversion is
not permitted.
CAUTION - FOR YOUR SAFETY
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
instructions.
gas supplier.
This appliance is only for use with the type of gas indicated on the rating plate.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-877-447-4768, 8:30 a.m. – 4:30 p.m., CST, Monday – Friday or
email us at customerservice@ghpgroupinc.com.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
VENT-FREE GAS FIREPLACE
1
Propane
Natural Gas
0418GF006S
ANSI Z21.11.2-2016
80-10-352 - 2022-11-04

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VFF-PH20LPB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for pleasant hearth VFF-PH20LPB

  • Page 1 VENT-FREE GAS FIREPLACE Propane Natural Gas WARNING: This appliance is equipped for (Natural or Pro- pane) gas. Field conversion is not permitted. 0418GF006S ANSI Z21.11.2-2016 CAUTION - FOR YOUR SAFETY WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS ........................... 2 Important Safety Information ......................3 ........................5 Product Features ..........................6 ............................6 ..........................7 Preparing for Installation........................8 Installation ............................11 Operation ............................23 Remote Control Operation.......................25 Care and Maintenance ........................32 ..........................35 Replacement Parts ......................... 37 Accessories ............................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION WARNING: FIRE, EXPLOSION, AND ASPHYXIATION HAZARD Improper adjustment, alteration, service, maintenance, or installation of this heater or its controls can cause death or serious injury. Read and follow instructions and precautions in User's Information Manual provided with this heater. IMPORTANT: WARNING: of this or any other appliance.
  • Page 4 SAFETY INFORMATION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is 3. If you smell gas • shut off gas supply • do not try to light any appliance 8.
  • Page 5 PRODUCT IDENTIFICATION VFF-PH(20NGB)(20NG)(20NG-C1)(20NG-2T1) VFF-PH(32NGB)(32NG)(32NG-H1)(32NG-2C1) VFF-PH(20LPB)(20LP)(20LP-C2)(20LP-2T2) VFF-PH(32LPB)(32LP)(32LP-H2)(32LP-2C2) VFF-PH(26NG)(26NG-T1)(26NG-2H1) VFF-PH(26LP)(26LP-T2)(26LP-2H2) Fireplace Fireplace Cabinet Cabinet Hood Hood Screen Screen Remote Transmitter Ignitor Button Ignitor Button Control Knob EI Receiver Control Knob Fig. 1 - Vent-Free Dual Fuel Fireplace Mantel Cabinet WARNING: warranty and could resuly in property damage and personal injury.
  • Page 6: Product Features

    PRODUCT FEATURES SAFETY PILOT ELECTRIC PUSH BUTTON IGNITION SYSTEM THERMOSTAT HEAT CONTROL temperature. See page 24. BLOWER KIT (OPTIONAL) State of Massachusetts: supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit. In the State of Massachusetts the gas cock must be a T-handle type.
  • Page 7 HOOD ASSEMBLY (IF REQUIRED) WARNING: Failure to position the parts in accordance with these diagrams or failure to or personal injury. Tools Required: • Phillips screwdriver • scissors Louver Shoulder Screw Firebox Top Sheet Metal Screen Screws Hood Fig. 3 - Assembling Hood Fig.
  • Page 8: Preparing For Installation

    PREPARING FOR INSTALLATION AIR FOR COMBUSTION AND VENTILATION WARNING: Nation Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code PRODUCING ADEQUATE VENTILATION 1. Unusually Tight Construction input rating of all appliances installed in that space. Rooms connecting directly with the space in Unusually Tight Construction fresh air.
  • Page 9 PREPARING FOR INSTALLATION DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Space: Includes the room in which you will install heater plus any adjoining rooms with 1. Determine the volume of the space Length × Width × Height = cu. ft. (volume of space) of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
  • Page 10 PREPARING FOR INSTALLATION Ventilation Air From Inside Building This fresh air would come from adjoining provide two permanent openings: one within 12 in. of the wall connecting the two spaces (see options 1 and 2, Fig. 4). You can also remove door into adjoining room (see option 3, Fig.
  • Page 11: Installation

    INSTALLATION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a help circulate the heat throughout the house. WARNING: WARNING: Never install the heater: •...
  • Page 12 INSTALLATION FIREPLACE CLEARANCES • where there is easy access for operation, inspection and service • in coldest part of room depth of the appliance. Minimum Clearances For Side Combustible Material, Side Wall and Ceiling follow diagram in Figure 6. Min. Min.
  • Page 13 INSTALLATION WARNING: grounded three-prong receptacle. BLOWER INSTALLATION (OPTIONAL) Remove Blower Access Panel. Access Panel Fireplace Top using 4 screws (F). Attach Power Cord (A) to Blower Access Panel. Screws Power Cord Access Panel Attach Temperature Sensor (C) to metal screws. Sheet Metal Screws...
  • Page 14 INSTALLATION with AUTO, OFF and MAN into line slot on the right corner. Keep wires yellow) into two male ports on Temperature Sensor. Insert the female plug on the white P1), into the corresponding male with P2) into the corresponding with P2).
  • Page 15 INSTALLATION Important Attach one in hole near the top and Hole Insert AUTO, OFF, MAN wires opening. NOTE: At this time, also unscrew close. Connect AUTO, OFF, MAN wires to the three corresponding male Match the "Auto" wire to the switch (E).
  • Page 16 INSTALLATION Control Panel and secure. Green Ground Wire and reattach Blower Access Panel to Outer Casing. Capture the Screw Access Panel Access Plate and Outer Casing Outer with the upper right screw. Casing Power Cord Electrical Wiring Diagram WHITE ~120V 60Hz GREEN BLACK...
  • Page 17 INSTALLATION CONNECTING TO GAS SUPPLY WARNING codes. CAUTION: WARNING as wellhead gas. Approved Gas Line or 1/2'' Fig. 9 - Regulator Conversion Fig. 10 - Gas Connection CAUTION or greater to allow proper volume gas to heater. If pipe is too small, loss of pressure will occur.
  • Page 18 INSTALLATION CAUTION: Use pipe joint sealant that is resistant to gas (PROPANE or NG). We recommend that you install a sediment trap in a supply line as shown in Fig. 10. sediment trap is not installed or is installed incorrectly, heater may not run properly. CAUTION: Avoid damage to regulator.
  • Page 19 ASSEMBLING LOGS VFF-PH(20LPB)(20LP)(20LP-C2)(20LP-2T2) VFF-PH(26LP)(26LP-T2)(26LP-2H2) WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts CAUTION: logs will create soot. Provided Logs: 5 It is very important to install the logs Use only logs supplied with heater. when installing.
  • Page 20 ASSEMBLING LOGS VFF-PH(32LPB)(32LP)(32LP-H2)(32LP-2C2) WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts CAUTION: logs will create soot. It is very important to install the logs Provided Logs: 5 Use only logs supplied with heater. when installing.
  • Page 21 INSTALLATION CHECKING GAS CONNECTIONS WARNING: WARNING: Pressure Testing Gas Supply Piping System 1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 1.
  • Page 22: Operation

    OPERATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: causing property damage, personal injury or loss of life. B. BEFORE LIGHTING WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. technician to inspect the appliance and to replace any part of the control system and any gas control LIGHTING INSTRUCTIONS Models Fig.
  • Page 23 OPERATION LEARN VFF-PH(32LPB)(32LP)(32LP-H2)(32LP-2C2) REMOTE Fig. 17 - Receiver & Control Knob Fig. 18 - Pilot to light pilot again. If after several tries the pilot still goes out, turn the service technician. MODE Fig.19 - Remote TO TURN OFF GAS TO APPLIANCE 3.
  • Page 24: Remote Control Operation

    REMOTE CONTROL OPERATION WALL CLIP SLOT BUTTON MODE BUTTON MODE BUTTON BUTTON BATTERY COMPARTMENT FRONT BACK MODE...
  • Page 25 REMOTE CONTROL OPERATION LCD - Liquid Crystal Display ROOM TEMP • TEMP TEMP TEMP TEMP TEMP ROOM...
  • Page 26 REMOTE CONTROL OPERATION ROOM TEMP TEMP ROOM Requires 4-AA 1.5V alkaline batteries Learning button Slide Switch REMOTE Remote Receiver...
  • Page 27 REMOTE CONTROL OPERATION Remote Receiver • Wire terminals • Receiver Slide Button LEARN • REMOTE • • • Remote Receiver Wire terminals Receiver Slide Button LEARN REMOTE Pulse Connection Concentric Valve PULSE MODE Terminals Receiver Slide Black Wire Button LEARN REMOTE Remote Receiver Red Wire...
  • Page 28 REMOTE CONTROL OPERATION • • •...
  • Page 29 REMOTE CONTROL OPERATION WALL CLIP SLOT WALL CLIP BATTERY COMPARTMENT • • • • • • •...
  • Page 30 OPERATION INSPECTING BURNERS PILOT FLAME PATTERN Fig. 20 - Correct Pilot Flame Pattern Fig. 21 - Incorrect Pilot Flame Pattern WARNING WARNING use with this heater.
  • Page 31: Care And Maintenance

    CARE AND MAINTENANCE BURNER FLAME PATTERN the log cures. 6-12 inches 2-3 inches Fig. 22 - Correct Burner Flame Pattern Fig. 23 - Incorrect Burner Flame Pattern WARNING: CAUTION: WARNING and property damage. BURNER ORIFICE HOLDER AND PILOT AIR INLET HOLE service person.
  • Page 32 CARE AND MAINTENANCE 1. Shut off unit including pilot. Allow unit to cool for at least 30 minutes. Burner Primary Air Inlet Holes Fig. 24 - Primary Air Inlet Slot on Burner Tube LP/NG Pilot Air Inlet Hole Fig. 25 - Pilot Inlet Air Hole LOG SET •...
  • Page 33 TROUBLESHOOTING WARNING: If you smell gas: • Shut off gas supply. • Do not try to light any appliance. IMPORTANT: WARNING: WARNING: and repair heater. CAUTION: SERVICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit You may feel your gas pressure is too low.
  • Page 34 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION ODS/pilot lights pressed in. in long enough. released. 3. Equipment shutoff valve is 3. Fully open equipment shutoff valve. not fully open. 4. Thermocouple connection is 4. Hand tighten until snug, and then loose. tighten ¼...
  • Page 35 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION White powder resi- 1. When heated, the vapors 1. Turn heater off when using furniture due forming within carpet cleaners, etc., turn products. adjacent walls or into white powder residue. furniture. Heater produces from paint, hair spray, glues, unwanted odors.
  • Page 36: Replacement Parts

    REPLACEMENT PARTS For replacement parts, call our customer service department at 1-877-447-4768, 8:30 a.m. – 4:30 p.m., CST, Monday – Friday. FIREBOX MODELS VFF-PH(20NGB)(20NG)(20NG-C1)(20NG-2T1), VFF-PH(20LPB)(20LP)(20LP-C2)(20LP-2T2), VFF-PH(26NG)(26NG-T1)(26NG-2H1) VFF-PH(26LP)(26LP-T2)(26LP-2H2), VFF-PH(32NGB)(32NG)(32NG-H1)(32NG-2C1), VFF-PH(32LPB)(32LP)(32LP-H2)(32LP-2C2) PART NUMBER ITEM DESCRIPTION Top Grille 700-S1014B 700-M1014B 700-L1014B Hood 700-S1012B 700-M1012B 700-L1012B Window Frame Assembly...
  • Page 37: Accessories

    REPLACEMENT PARTS LIST For replacement parts, call our customer service department at 1-877-447-4768, 8:30 a.m. – 4:30 p.m., CST, Monday – Friday. VFF-PH(20LPB)(20LP)(20LP-C2)(20LP-2T2) VFF-PH(32LPB)(32LP)(32LP-H2)(32LP-2C2) VFF-PH(26LP)(26LP-T2)(26LP-2H2) ITEM PART NUMBER DESCRIPTION Log Set (complete) 700-S1018 700-M1018 700-L1018 1 - 1 Log 1 700-S1018-01 700-M1018-01 700-L1018-01...
  • Page 39 This limited warranty is extended to the original retail purchaser of this heater and warrants against any years years...
  • Page 40 GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302 Tel: (877) 447-4768 www.ghpgroupinc.com GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302...
  • Page 41 CHIMENEA DE COMBUSTIBLE DUAL A GAS DE TIRO NATURAL Propano No. DE MODELO VFF-PH(20LPB)(20LP)(20LP-C2)(20LP-2T2) VFF-PH(26LP)(26LP-T2)(26LP-2H2) VFF-PH(32LPB)(32LP)(32LP-H2)(32LP-2C2) Gas Natural No. DE MODELO ADVERTENCIA: Este VFF-PH(20NGB)(20NG)(20NG-C1)(20NG-2T1) aparato está equipado para VFF-PH(26NG)(26NG-T1)(26NG-2H1) gas (Natural o Propano). La VFF-PH(32NGB)(32NG)(32NG-H1)(32NG-2C1) conversión de campo no está permitida.
  • Page 42 TABLA DE CONTENIDO ............................... 2 Información de seguridad importante ......................3 ..........................5 Características del producto ........................... 6 Desempaque ..............................6 Ensamblaje del extractor ..........................7 Preparación para la instalación ........................8 Instalación ..............................11 Operación ..............................23 Cuidado y mantenimiento ..........................26 Resolución de fallas .............................
  • Page 43: Información De Seguridad Importante

    INFORMACIÓN DE SEGURIDAD IMPORTANTE ADVERTENCIA: PELIGRO DE INCENDIO, EXPLOSIÓN Y ASFIXIA La alteración, el ajuste, servicio, mantenimiento o la instalación inadecuada de este calentador o sus controles pueden causar lesiones graves o incluso la muerte. Lea y siga las instrucciones y precauciones en el Manual de información del usuario proporcionado en este calentador.
  • Page 44 INFORMACIÓN DE SEGURIDAD 1. Este aparato es solo para ser usado con el tipo de gas indicado en la placa de características. Este aparato no es convertible para uso con otros gases. 2. No coloque el(los) tanque(s) de suministro de propano/PL dentro de ninguna estructura. Coloque el(los) tanque(s) de suministro de propano/PL en exteriores.
  • Page 45 IDENTIFICACIÓN DEL PRODUCTO VFF-PH(20NGB)(20NG)(20NG-C1)(20NG-2T1) VFF-PH(32NGB)(32NG)(32NG-H1)(32NG-2C1) VFF-PH(20LPB)(20LP)(20LP-C2)(20LP-2T2) VFF-PH(32LPB)(32LP)(32LP-H2)(32LP-2C2) VFF-PH(26NG)(26NG-T1)(26NG-2H1) VFF-PH(26LP)(26LP-T2)(26LP-2H2) Gabinete de Gabinete de chimenea chimenea Extractor Extractor Pantalla Pantalla Leño Transmisor remoto Leño Botón del Botón del encendedor encendedor Perilla de control Receptor EI Perilla de control Fig. 1 - Chimenea de combustible dual de tiro natural Gabinete del marco NOTA: La chimenea es instalada en la repisa de la chimenea a través de la abertura frontal de la...
  • Page 46: Características Del Producto

    CARACTERÍSTICAS DEL PRODUCTO PILOTO DE SEGURIDAD Este calefactor tiene un piloto con un sistema de apagado de seguridad de Detección de disminución de principal en el caso de que la llama se apague. SISTEMA DE IGNICIÓN ELÉCTRICA DE BOTÓN DE PRESIÓN Este calefactor está...
  • Page 47: Ensamblaje Del Extractor

    ENSAMBLAJE DEL EXTRACTOR (SI SE REQUIERE) ADVERTENCIA: Tenga siempre la pantalla en su lugar antes de operar la chimenea. Esto evita ADVERTENCIA: No colocar las piezas de acuerdo con estos diagramas o no usar solamente o lesiones personales. Herramientas requeridas: •...
  • Page 48: Preparación Para La Instalación

    PREPARACIÓN PARA LA INSTALACIÓN AIRE PARA LA COMBUSTIÓN Y VENTILACIÓN ADVERTENCIA: Este calefactor no deberá ser instalado en una habitación o espacio a menos que el volumen requerido de aire de combustión de interiores sea proporcionado por el método descrito en el Código Nacional de Gas Combustible, ANSI Z223.1/NFPA 54, el Código Internacional de Gas Combustible, o códigos locales aplicables.
  • Page 49 PREPARACIÓN PARA LA INSTALACIÓN DETERMINACIÓN DEL FLUJO DE AIRE FRESCO A LA UBICACIÓN DEL CALEFACTOR Espacio: Incluye la habitación en la cual instalará el calefactor más cualquier habitación contigua a pasillos sin puertas o rejillas de ventilación entre las habitaciones. 1.
  • Page 50 PREPARACIÓN PARA LA INSTALACIÓN contiguo. Cuando se ventila a un espacio no 12 pulg. aberturas permanentes: una dentro de 12 pulg. de la pared que conecta los dos espacios Rejillas de ventilación en habitación contigua, (ver opciones 1 y 2, Fig. 4). También puede Opción 2 Retire la Rejillas de...
  • Page 51: Instalación

    INSTALACIÓN AVISO: Este calefactor está diseñado para ser usado como calor complementario. Use este calefactor junto con su sistema de calefacción primario. No instale este calefactor como su fuente primaria de calor. Si tiene un sistema de calefacción central, puede poner a funcionar un soplador de circulación del sistema mientras usa el calefactor.
  • Page 52 INSTALACIÓN ESPACIOS LIBRES DE LA CHIMENEA PRECAUCIÓN: Si instala la chimenea en la cochera de su casa • el piloto y el quemador de la chimenea deben estar al menos a 18" sobre el piso. • coloque la chimenea donde vehículos en movimiento no la golpeen. •...
  • Page 53 INSTALACIÓN ADVERTENCIA: Este aparato está equipado con un enchufe de tres terminales (conexión a tierra) para su protección contra peligro de choque eléctrico y debe ser conectado directamente en un receptáculo de tres terminales con conexión a tierra apropiada. La caja de fuego debe ser desconectada del suministro de gas y retirada del marco antes de instalar INSTALACIÓN DEL SOPLADOR (OPCIONAL) Retire el panel de acceso del soplador.
  • Page 54 INSTALACIÓN Importante: Inserte los cables marcados con AUTO, OFF y MAN en la ranura de línea en la esquina derecha. Mantenga los cables cerca del fondo. Inserte dos enchufes hembra de dos cables marcados con T1 y T2 (negro y amarillo) en dos puertos machos en el sensor de temperatura.
  • Page 55 INSTALACIÓN Inserte el enlace del soplador (enchufe macho) en el enlace de energía (puerto hembra). Importante: Ate los cables con amarres de cable (G), y sujete los amarres de cable (G) en agujeros en la parte trasera de la cubierta exterior. Sujete uno en el agujero cercano a la cubierta y otro en el agujero cercano al fondo.
  • Page 56 INSTALACIÓN Presione el interruptor oscilante (E) en el panel de control y asegure. Tierra verde Compruebe que todos los cables Cable estén seguros y reinstale el panel de acceso del soplador en la cubierta Tornillo exterior. Atrape el el cable de tierra Panel de acceso verde entre la la placa de acceso y la cubierta exterior con el tornillo...
  • Page 57 INSTALACIÓN CONEXIÓN AL SUMINISTRO DE GAS ADVERTENCIA todos los códigos locales. PRECAUCIÓN: Nunca conecte el calefactor directamente al suministro de gas. Este calefactor requiere un regulador externo (no suministrado). El regulador externo entre el suministro de gas y el calefactor debe ser instalado.
  • Page 58 INSTALACIÓN PRECAUCIÓN: Use sellador de juntas de tubo que sea resistente al gas (PROPANO O GN). Recomendamos una trampa de sedimentos en una línea de suministro como se muestra en la Fig. 10. Ubique la trampa de sedimentos donde esté al alcance para limpieza y que no existan probabilidades de que se congele. Instálela en el sistema de tuberías entre el suministro de combustible y el calefactor.
  • Page 59 ENSAMBLAJE DE LOS LEÑOS VFF-PH(20NGB)(20NG)(20NG-C1)(20NG-2T1) VFF-PH(20LPB)(20LP)(20LP-C2)(20LP-2T2) VFF-PH(26NG)(26NG-T1)(26NG-2H1) VFF-PH(26LP)(26LP-T2)(26LP-2H2) ADVERTENCIA: No colocar las piezas de acuerdo con estos diagramas o no usar solamente piezas personales. PRECAUCIÓN: Después de la instalación y a partir de alli periódicamente, revise para asegurarse de que ninguna llama amarilla entre en contacto con los leños.
  • Page 60 ENSAMBLAJE DE LOS LEÑOS VFF-PH(32NGB)(32NG)(32NG-H1)(32NG-2C1), VFF-PH(32LPB)(32LP)(32LP-H2)(32LP-2C2) ADVERTENCIA: No colocar las piezas de acuerdo con estos diagramas o no usar solamente piezas personales. PRECAUCIÓN: Después de la instalación y a partir de alli periódicamente, revise para asegurarse de que ninguna llama amarilla entre en contacto con los leños. Cuando el calefactor se ajusta a Alto, revise para ver si las llamas amarillas entran en contacto con los leños.
  • Page 61 INSTALACIÓN REVISIÓN DE LAS CONEXIONES DE GAS ADVERTENCIA: Pruebe toda la tubería y conexiones de gas en contra de fugas después de la instalación y el servicio. Corrija todas las fugas de inmediato. ADVERTENCIA: Nunca use una llama abierta para revisar en busca de fugas. Aplique una mezcla de jabón líquido y agua en todas las juntas.
  • Page 62: Operación

    OPERACIÓN PARA SU SEGURIDAD LEA ANTES DEL ENCENDIDO ADVERTENCIA: Si no sigue estas instrucciones exactamente, puede resultar un incendio o explosión ocasionando daños a la propiedad, lesiones personales o la muerte. A. Este aparato tiene una piloto que debe ser encendido por el encendedor electrónico. Cuando encienda el piloto, siga estas instrucciones exactamente.
  • Page 63 OPERACIÓN Modelos VFF-PH(32NGB)(32NG)(32NG-H1)(32NG-2C1) LEARN VFF-PH(32LPB)(32LP)(32LP-H2)(32LP-2C2) 1. ¡ALTO! Lea la información de seguridad a la izquierda de esta etiqueta. 2. Abra el panel de acceso inferior ubicado abajo de la pantalla de la chimenea. REMOTE Fig. 17 - Receptor y perilla de control 4.
  • Page 64 OPERACIÓN DEL CONTROL REMOTO WALL CLIP ENCENDIDO DE MODO MODE APAGADO A JU STE FRENTE PARTE TRASERA...
  • Page 65 OPERACIÓN DEL CONTROL REMOTO LCD - Pantalla de cristal líquido TEMP...
  • Page 66 OPERACIÓN DEL CONTROL REMOTO...
  • Page 67 OPERACIÓN DEL CONTROL REMOTO Receptor remoto Terminales de cable Botón deslizante LEARN receptor REMOTE Receptor remoto Terminales de cable Conexión de pulso Válvula concéntrica PULSE MODE Terminals Receiver Slide Button Button LEARN REMOTE Remote Receiver...
  • Page 68 OPERACIÓN DEL CONTROL REMOTO...
  • Page 69 OPERACIÓN DEL CONTROL REMOTO R A N U R A D EL GANCHO DE PARE G A N C H O DE P A R E D COMPARTIMIENTO DE LA BATERÍA •...
  • Page 70 OPERACIÓN INSPECCIÓN DE LOS QUEMADORES Revise con frecuencia el patrón de la llama del piloto y los patrones de la llama del quemador. PATRÓN DE LA LLAMA DEL PILOTO La Figura 20 muestra un patrón correcto de la llama del piloto. La Figura 21 muestra un patrón incorrecto de la llama del piloto.
  • Page 71: Cuidado Y Mantenimiento

    CUIDADO Y MANTENIMIENTO PATRÓN DE LA LLAMA DEL QUEMADOR La Figura 22 muestra un patrón correcto de la llama del quemador. La Figura 23 muestra un patrón incorrecto de la llama del quemador. El patrón incorrecto de la llama del quemador muestra puntas de llama esporádicas e irregulares.
  • Page 72 CUIDADO Y LIMPIEZA 1. Apague la unidad incluyendo el piloto. Deje que la unidad se enfríe durante 30 minutos. de polvo y suciedad (Ver Fig. 24). 3. Sople aire a través de los puertos/ranuras y agujeros en el quemador. grandes de polvo, suciedad, pelusa o pelo de mascotas con un paño suave o con una aspiradora. 6.
  • Page 73: Resolución De Fallas

    RESOLUCIÓN DE FALLAS ADVERTENCIA: Si huele gas: • Apague el suministro de gas • No trate de encender ningún aparato. • LLame de inmediato a su proveedor de gas del teléfono de un vecino. Siga las instrucciones del proveedor de gas. •...
  • Page 74 RESOLUCIÓN DE FALLAS PROBLEMA CAUSA POSIBLE ACCIÓN CORRECTIVA 1. La perilla de control no está El ODS/piloto enciende 1. Oprima por completo la perilla de control completamente presionada. pero la llama se apaga 2. La perilla de control no está cuando la perilla de 2.
  • Page 75 RESOLUCIÓN DE FALLAS PROBLEMA CAUSA POSIBLE ACCIÓN CORRECTIVA Residuo de polvo blanco 1. Cuando se calientan, los vapores 1. Apague el calefactor cuando use que se forma dentro de del pulidor de muebles, cera, pulidor de mueble, cera, limpiador de alfombra o la caja del quemador o limpiadores de alfombra, ect.
  • Page 76: Piezas De Repuesto

    PIEZAS DE REPUESTO Para piezas de repuesto, llame a nuestro departamento de servicio al cliente al 1-877-447-4768, de lunes a viernes, de 8:30 a.m. a 4:30 p.m., hora estándar del Centro. MODELOS DE CAJA DE FUEGO VFF-PH(20NGB)(20NG)(20NG-C1)(20NG-2T1), VFF-PH(20LPB)(20LP)(20LP-C2)(20LP-2T2), VFF-PH(26NG)(26NG-T1)(26NG-2H1), VFF-PH(26LP)(26LP-T2)(26LP-2H2), VFF-PH(32NGB)(32NG)(32NG-H1)(32NG-2C1), VFF-PH(32LPB)(32LP)(32LP-H2)(32LP-2C2) NÚM DE NÚM DE PIEZA...
  • Page 77: Accesorios

    LISTA DE PIEZAS DE REPUESTO Para piezas de repuesto, llame a nuestro departamento de servicio al cliente al 1-877-447-4768, de lunes a viernes, de 8:30 a.m. a 4:30 p.m., hora estándar del Centro. VFF-PH(20NGB)(20NG)(20NG-C1)(20NG-2T1) VFF-PH(32NGB)(32NG)(32NG-H1)(32NG-2C1) VFF-PH(20LPB)(20LP)(20LP-C2)(20LP-2T2) VFF-PH(32LPB)(32LP)(32LP-H2)(32LP-2C2) VFF-PH(26NG)(26NG-T1)(26NG-2H1) VFF-PH(26LP)(26LP-T2)(26LP-2H2) NÚM DE NÚM DE PIEZA DESCRIPCIÓN CANTIDAD...
  • Page 79: Garantía

    Garantía GARANTÍA LIMITADA: Esta garantía limitada se extiende al comprador original al por menor de este conjunto de calentador y garantiza contra cualquier defecto en materiales y mano de obra durante un periodo de (2) años a par tir de la fecha de venta al por menor. GHP Group, Inc., a su opción, proporcionará piezas de reemplazo o reparará...
  • Page 80 REGISTRO DE LA GARANTÍA IMPORTANTE: Le urgimos que llene su tarjeta de registro de la garantía en el plazo de catorce (14) después de la fecha de compra También puede registrar su garantíaen internet en www.ghpgroupinc.com. Complete el número de serie. Conserve esta porción de la tarjeta para sus registros.