Supplementary User Instructions
11. Thorough examination
A thorough examination should be carried out by
a competent person at intervals not exceeding
six months, and at sooner intervals in accordance
with local laws or where the equipment is used in
extreme environments.
Components that have cracks, are visibly distorted
or twisted, severely corroded, or have gouges
in excess of 10% of the thickness of the material
should be discarded and replaced, or repaired. The
thorough examination should be carried out by a
competent inspector.
Fasteners should be inspected prior to each use,
and discarded if any visible damage to the bolt
shank or the thread.
12. Repair
Repairs must be done by Modulift if possible, but
in exceptional circumstances repairs can be done
by a third party in strict accordance with Modulift's
requirements & express approval.
It is essential that Modulift is contacted to discuss
any repairs before proceeding, otherwise the
Modulift declaration becomes invalid.
13. End of life
Modulift products are generally made from
structural mild steel that can be widely recycled.
Modulift UK Ltd tel: +44(0)1202 621511 email: sales@modulift.com www.modulift.com