Connecting The Load - Kubota GL6000-AUS Operator's Manual

Diesel generator
Hide thumbs Also See for GL6000-AUS:
Table of Contents

Advertisement

12

CONNECTING THE LOAD

CONNECTING THE LOAD
B Connection Notes
WARNING
To avoid personal injury:
A Before
the
connected to a building's electrical
system, a licensed electrician must
install an isolation (transfer) switch
in the building's main fuse box. The
switch is the connection point for
generator
power
selection of generator or main line
power to the building. This will
prevent the generator from charging
the main power line (backfeeding)
when the main power supply has
failed or has been turned off for line
repair. Backfeeding can electrocute
or
injure
personnel.
Also,
building electrical system damage
can occur when normal operating
power returns if unit is used without
an isolation switch.
1. Avoid connecting the generator to commercial
power outlet.
2. Avoid connecting the generator in parallel with any
other generator.
B Connecting the Load (Terminal output
Model)
WARNING
To avoid personal injury:
A Connect or disconnect the load to
the AC receptacles or terminals only
when the engine is stopped.
A For your safety, close the terminal
cover after connecting the load.
A For your safety, secure the cover
with the lock bolts.
generator
can
be
and
allows
line
maintenance
generator
and
1. Turn OFF the circuit breaker on the control panel.
2. Connect the load to the A.C. output terminals.
3. Be sure to close the terminal cover after connecting
the load.
(1) Circuit breaker
(2) Terminals (output)
(3) Cover lock bolt