TABLE OF CONTENTS Key to symbols used ..........................3 Safety instructions ..........................3 Important information Warranty ....................................3 Liability ....................................3 Guarantee ....................................4 Technical information Description ..................................4 Use .......................................5 Application limits.................................6 Components Ventilation unit ..................................6 Operator terminal ................................6 Commissioning Installation inspection .................................7 Switching on ..................................7 Maintenance Supply air and extract air filter ............................7...
The comfort ventilation unit is only allowed to be used Indicate danger to machines and for the purpose for which it was designed and which has installations. been approved by Hoval. Any other use is impermissible. Application in the following areas is prohibited: Safety instructions •...
• Temperature efficiency up to 90% • Degree of humidity recovery up to 95% • Transmission performance can be adjusted With the acquisition of a Hoval unit, you also obtain continuously comprehensive warranty cover under the Hoval terms • No preheating required (down to -20°C) of warranty.
However, this requires an air-conditioning system functions: to be present in order to provide the necessary cooling • Operation of all Hoval units connected to the bus. in the room. The enthalpy recovery system extracts heat • Authorisation management for operation.
TECHNICAL INFORMATION, COMPONENTS AND COMMISSIONING Components Opening the windows As a rule, you will not require heating in summer and thus no heat recovery via your comfort ventilation unit. Ventilation unit HomeVent comfort ventilation unit. You can open doors ® and windows as you wish.
® Thorough cleaning of the HomeVent ® mounted securely and vibration-free on the wall, Comfort ventilation unit by Hoval Cus- ceiling or floor. tomer Service or an installer trained by Hoval. With ceiling installation: Conclude a service agreement with Ho- Beware of falling parts.
MAINTENANCE 7.1.2 "Filter change" procedure • The filters are not reusable (washable). Disconnect the HomeVent comfort ventilation ® • The filters are 100 % incinerable unit power plug. (residual waste). Make a note of the date when you replaced the filters on the log sheet. Order new filters when you have replaced the old ones to ensure that you can change the filters without delay the next...
Push in both prefilter cover. Slide in insert Insert plug Insert prefilter cover. Spare parts Use only genuine Hoval accessories. You will find the ordering addresses on the back page of this manua. Designation Filter class Art.No.
LOGS Logs Plant logs Installer ............................................................................................................................................................................Electrician ............................................................................................................................................................................Hoval Customer Service (see back page of this manual) ................................... Subject to modifications 4 216 974 / 02...
LOGS Filter maintenance log Please make a note of the actions you have carried out in the log below! E.g.: When you have inspected the sup- ply air filter, circle the 'I' in the supply air filter column and enter the date on which the inspection was carried out. If servicing tasks are performed by several persons, the person who carried out the task should enter their name in the last column in case any questions arise later.