System weight
Table 8. PowerEdge XR4000r system weight
System configuration
Weight of chassis without sleds
Weight of chassis with sleds and bezel and witness node
Table 9. PowerEdgesystemweight handling recommendations
Chassis weight
40 pounds - 70 pounds
70 pounds- 120 pounds
≥ 121 pounds
Witness cooling fan specifications
The PowerEdge XR4000r system supports one standard fan with Normal air flow (NAF) or Reverse air flow (RAF) for witness
sled cooling.
Table 10. Cooling fan specifications
Fan type
Standard (STD) fan (60
mm cable length)
NOTE:
The cooling fan installed in the chassis is used for optional witness sled cooling.
PSU specifications
The PowerEdge XR4000r system supports up to two AC or DC power supply units (PSUs).
Table 11. PSU specifications
PSU
Class
Heat
dissipation
(maximum
) (BTU/hr)
1800W
Titaniu
6750 BTU/
Mixed
m
hr
Mode
6750 BTU/
hr
1400 W
Platinu
5250 BTU/
Mixed
m
hr
Mode
14
Technical specifications
Label color
No label
Frequency
Voltage
(Hz)
200 - 240 V
50/60 Hz
AC
240 V DC
NA
100 - 240 V
50/60 Hz
AC
Maximum weight (with all drives/SSDs)
7.96 kg (17.54 pound)
19.14 kg (42.20 pound)
Description
Recommend two person to lift
Recommend three person to lift
Recommend to use a server-lift
Label image
AC
High line
200–240 V
1800W
NA
1400 W
DC
Low line
100–120 V
NA
NA
NA
1800 W
1050 W
NA
Current (A)
10 A
8.2 A
12 A - 8 A