Safety precautions Although this product was designed to be used safely, failing to use it correctly may result in an accident. To ensure safety, observe all warnings and cautions while using the product. Cautions for the product Do not subject the product to strong impact to avoid malfunction. Do not disassemble, modify or attempt to repair the product.
Notes on use Be sure to read the connected device’s user manual before use. When the product is used for a long time, the product may become discolored due to ultraviolet light (especially direct sunlight) and wear. Make sure to hold the plug when connecting and disconnecting the cable. The cable may become severed or an accident may occur if you pull on the cable itself.
Using the product Connect the product to a device with a microphone input (balanced input) for use. Use the product with the front part facing the sound source.
Connection procedure The output connector is an XLR-M type with polarity as shown in the figure below. PIN1 (ground) PIN2 (hot) PIN3 (cold)
Page 7
Cleaning Get into the habit of regularly cleaning the product to ensure that it will last for a long time. Do not use alcohol, paint thinners, or other solvents for cleaning purposes. Wipe dirt off the product with a dry cloth. If the cables become dirty because of sweat, etc., wipe them with a dry cloth immediately after use.
Specifications Element Dynamic Polar pattern Hypercardioid Frequency response 60 to 16,000 Hz Open circuit sensitivity -52 dB (0 dB = 1 V/Pa, 1 kHz) Impedance 600 ohms Weight 262 g (9.2 oz) Dimensions 181.5 mm (7.1”) long, 50 mm (2.0”) maximum body diameter Output connector Integral 3-pin XLR-M type AT8470 stand clamp for 5/8”-27 threaded stands, 5/8”-27 to 3/8”-16 threaded...
Need help?
Do you have a question about the ATS99 and is the answer not in the manual?
Questions and answers