Fan Load (BLUE Wire) = Fan: 1/4 Hp, LED/CFL: 300W, Incandescent/Halogen: 600W, ELV/MLV: 400VA
Light Load (RED Wire) = 150W LED/CFL, 250W Incandescent/Halogen, 200VA Magnetic Low-Voltage, 250VA Electronic Low-Voltage, 2A Resistive
WARNINGS:
• TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT
BREAKER OR FUSE, AND TEST THAT THE POWER IS OFF BEFORE WIRING!
• TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to
control a receptacle or a load in excess of the specified rating.
• To be installed and/or used in accordance with electrical codes and regulations.
• If you are not sure about any part of these instructions, consult an electrician.
Features
Leviton's Combination Occupancy Sensor with Fan Switch senses when someone
enters and leaves the room, and turns the lights ON and OFF accordingly. The sensor
also has a second switch that can control fans or other loads. Some other features are:
• A sensing angle of 180 degrees, and a 30 ft x 30 ft sensing coverage area.
• Adjustable ambient light, time delay, and area of coverage controls.
• An indicator light that alerts you to the device's status.
• A second load switch for manual ON/OFF control, or program as a countdown timer
that turns the load OFF automatically after the programmable time period
(15, 30, or 45 minutes).
• Adjustable time delay settings for 1, 5, 10, and 20 minutes, a Test mode that turns
the device on for 5 seconds, and a Temporary Disable mode that disables the
Auto-on feature.
• Built-in Zero Cross turn-ON technology to extend the life of switching relays.
• Color change kits available in white, light almond, ivory, black, brown, and gray.
Location
CAUTIONS:
• DO NOT mount the device directly above a heat source, in a location where hot or
cold drafts blow directly on the sensor, or where there may be unintended motion in
the sensor's field-of-view, such as in a hallway.
• The device also responds to temperature changes, which may lead to
inadvertent operation.
Mount the device at a level that can detect motion.
You Will Need
• Slotted or Phillips screwdriver
• Electrical tape
• Cutters
• Pliers
Installation
WARNING: TO AVOID FIRE, SHOCK, OR DEATH, turn the power OFF at the
circuit breaker or fuse, and test that the power is OFF before wiring.
1. Identify your wires (most common):
NOTE: A Neutral wire (if present) or a Ground wire is required for operation.
If the wiring in the wallbox is different from this configuration, consult an electrician.
No Neutral wire
To and From
To and From
Fan/Light
Fan/Light
LOAD 1
LOAD 1
LOAD 2
LOAD 2
LINE
LINE
GROUND
GROUND
2a. Wire (when a Neutral wire is NOT present)
Work on one connection at a time, and connect the wires, as shown below.
FAN LOAD
FAN LOAD
(Blue)
(Blue)
LIGHT LOAD
LIGHT LOAD
LIGHT
LIGHT
(Red)
(Red)
LOAD
LOAD
GROUND
GROUND
(Green
(Green
sleeved wire)
sleeved wire)
GROUND
GROUND
(Green/Yellow)
(Green/Yellow)
Combination Occupancy Sensor with Fan Switch
Cat. No. DOD05 - INDOOR USE ONLY. 120VAC, 60Hz - Single Pole Only
INSTALLATION INSTRUCTIONS
With Neutral wire
To Fan and Light
To Fan and Light
LOAD 1
LOAD 1
LOAD 2
LOAD 2
NEUTRAL
NEUTRAL
GROUND
GROUND
LINE
LINE
From
From
Branch Circuit
Branch Circuit
To and From
To and From
Fan/Light
Fan/Light
FAN LOAD
FAN LOAD
LINE
LINE
LINE
LINE
(Black)
(Black)
GROUND
GROUND
CAUTIONS:
• DO NOT attempt to service or repair. There are no user-serviceable components.
• Use this device with COPPER OR COPPER-CLAD WIRE ONLY.
• To avoid damage to the product, DO NOT use disinfecting products, including
foggers, sprays or other types of atomized cleaning agents.
• DO NOT spray liquid onto the product.
• To clean, use a damp cloth with mild soap.
2b. Wire (when a Neutral wire IS present)
Remove the Green sleeve from the White wire.
Work on one connection at a time, and connect wires, as shown below.
FAN LOAD
FAN LOAD
(Blue)
(Blue)
LIGHT LOAD
LIGHT LOAD
LIGHT
LIGHT
(Red)
(Red)
LOAD
LOAD
NEUTRAL
(White)
GROUND
GROUND
(Green/Yellow)
(Green/Yellow)
3. Test and Mount
a. Restore power. Wait 10-20 seconds for the sensor to power up.
b. During power up, the Green light blinks once every 5 seconds.
c. Push the Fan and Light buttons to test each load.
d. Turn the power OFF at circuit breaker.
e. Gently, push the wires into the wallbox, and attach the device to the wallbox.
f. Install a wallplate.
g. Restore the power at the circuit breaker or fuse.
Operation
LED
(Red)
LED
(Green)
Fan
Light
Mode or Status
LED Color
Power Up
Green
Light Load OFF
Green
Light Load ON
All
Temporary Disable
Green
Motion Detected
Red
Test Mode
Red
Program Mode
Red/Green
Changing Your Device Color
Remove
Available in White (W), Light Almond (T), Ivory (I), Brown (B), Black (E), and
Gray (G) (DHDKT-1Lx).
DI-000-DOD05-02A
ENGLISH
To Fan and Light
To Fan and Light
FAN LOAD
FAN LOAD
NEUTRAL
LINE
LINE
LINE
LINE
(Black)
(Black)
GROUND
GROUND
From
From
Branch Circuit
Branch Circuit
LED Status
Blinks once every 5 seconds.
On
Off
Double-flash every 2 seconds.
Blinks once with every
motion detected.
Blinks once every 2 seconds.
See the Programming Table.
Replace
Need help?
Do you have a question about the DOD05 and is the answer not in the manual?
Questions and answers