Manual Restart (Standard Models Only); Configuration Of Restart Mode - Datasensing SH4 BASE-STANDARD Product Reference Manual

Safety light curtains
Table of Contents

Advertisement

FUNCTIONS

Manual Restart (Standard models only)

After the ESPE has detected an opaque object in the controlled area, the light curtain
begins its normal functioning only after a proper signal pattern on RESTART input (pin 1,
usually connected to a normally open push button) and after the object has been
removed from the controlled area; see the restart timing diagram below:
OSSDs
INTERLOCK STATUS
RESTART INPUT
The outputs go high after a time that is the maximum value between the recovery time
and the time of restart high (more or equal to 0.5 s), so this time can be any between
0.5 s and 5 s.
In the timing diagram above the object is already removed.
CAUTION

Configuration of Restart mode

The configuration of Restart mode is done by connecting the MAN_AUTO signal (pin 8,
red) to one of the OSSD as described below:
38
SH4 BASE-STANDARD
Figure 6: OSSDs behavior in Manual Restart Mode and Restart Pattern
Carefully assess risk conditions and reset modes. In applications protect-
ing access to dangerous areas, the automatic reset mode is potentially
unsafe if it allows the operator to pass completely beyond the sensitive
area.
In this case, the manual reset or, for example, the manual reset of the SE-
SR2 relay (see "Couple arms" on page 79) is necessary.
OSSD1, pin 5 (grey) to setting the automatic restart function
OSSD2, pin 6 (pink) to setting the manual restart function
0.5 S
ON
OFF
ON
OFF
24V
0V