Height of the detection zone

The controlled height is the height protected by the safety light curtain.
In SH4-14/30 Protected Height is equal to ESPE total length: no dead zone is present.
In SH4-2/3/4, first beam center is positioned at 130 mm from light curtain bottom, pro-
tected height is defined as the distance between uppermost and lowermost beam
centreline.
Referring to the figure above the protected height is reported in the table here below.
SH4-14/30
PROTECTED
AREA
Operating distance
Figure 2: Detection zone
MODEL
SH4-14/30-0300-X-X
SH4-14/30-0450-X-X
SH4-14/30-0600-X-X
SH4-14/30-0750-X-X
SH4-14/30-0900-X-X
SH4-14/30-1050-X-X
SH4-14/30-1200-X-X
SH4-14/30-1350-X-X
SH4-14/30-1500-X-X
SH4-14/30-1650-X-X
SH4-14/30-1800-X-X
SH4-14/30-1950-X-X
SH4-14/30-2100-X-X
SH4-14/30-2250-X-X
SH4-2-0500-X(X)-X-(X)
SH4-3-0800-X(X)-X-(X)
SH4-4-0900-X(X)-X-(X)
SH4-4-1200-X(X)-X-(X)
HOW TO CHOOSE THE DEVICE
SH4-2/3/4
PROTECTED
AREA
Operating distance
PROTECTED HEIGHT (mm)
300
450
600
750
900
1050
1200
1350
1500
1650
1800
1950
2100
2250
500
800
900
1200
PRODUCT REFERENCE GUIDE